1OM-1086-002.pdf - 第91页

1. Normal Automatic Operation Flow of Automatic Operations Change of Product for Automatic Operation Refer to "Chapter 2 Operation (Supervisor)" for details. Inspections Work before Automatic Operation Refer to…

100%1 / 355
Section 3
Scope of Automatic Operation
0211-005 Chapter 1 3-1 Tg0582-PM-D1
This section outlines the items to be prepared and con-
firmed before automatic operation and how to start or end
the operation.
1. Normal Automatic Operation
Flow of Automatic Operations
Change of Product for Automatic Operation
Refer to "Chapter 2 Operation (Supervisor)" for details.
Inspections Work before Automatic Operation
Refer to below for details.
1.1.1 Checking of Power Supply and Air Pressure
1.1.2 Checking of Safety Door
Preparation before Automatic Operation
Refer to below for details.
1.2.1 Power ON Operation
1.2.2 "AUTO OPERATION" Window
1.2.3 Preparation for Solder Paste and P.C.B.’s
Start of Automatic Operation
Refer to below for details.
1.3 Start of Automatic Operation
Interruption of Automatic Operation
Refer to below for details.
1.4.1 Replenishment of Components and P.C.B.’s
1.4.2 Stop Operation with the [STOP] Button
1.4.3 Stop Operation by Selection of "Auto Stop Setting" Tab
Stop and Re-start of Automatic Operation
Refer to below for details.
1.5.1 Interruption with [EMERGENCY STOP] Switch
End of Automatic Operation
Refer to the following for details.
1.6 End of Automatic Operation
Shut-Down Operation
Refer to the following for details.
1.7 Shut-Down Operation
1. Normal Automatic Operation
0211-005 Chapter 1 3-2 Tg0582-PM-D1
Fig.1C1
Fig.1C2
1.1 Inspections Work before Operation
1.1.1 Checking of Power Supply and Air Pressure
(1) Confirmation of Power Supply
Confirm that the local main breaker connected with this machine is
"ON".
• Voltage : 200 ± 20 V AC, 3-Phase
• Apparent Power : Approx. 5kVA
(2) Confirmation of Air Pressure
Confirm that the air pressure is set to the value specified below.
• Main Pressure: 0.39 MPa (4 kgf/cm
2
)
Fig. 1C6
(a) The pressure switch is factory-set to "0.34 MPa (3.5 kgf/
cm
2
). Be sure not to change the setting.
(b) Use of Dry and Clean Air
If moisture, oil, or dust enters the pneumatic equipment
(an air cylinder, etc.) of this machine, it may result in a break-
down of the machine. Be sure to use dry and clean air.
Dry and Clean Air:
Moisture : Dew Point -17°C or lower (Atmospheric Pres-
sure)
Oil : 0.1 mg/m
3
(ANR) or less
Dust : Solid Material 0.01 µm or less
1.1 Inspections Work before Operation
Do not change the set pressure. Otherwise, an pneu-
matic equipment will not work correctly.
CAUTION
0304-006 Chapter 1 3-3 Tg0582-PM-D1