444CEMM1 - 第134页
Page 1-72 Check Every 560 Hours (Once a Month) 1-5-3 How to Check the Setting of the Blow Pressure 1. Press Machine adjust . • The “ Machine adjustment menu ” screen appears. 2. Press Output check . • The “ Output check …

Page 1-71
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Month)
444C-E-MMA01-A09-08
Procedure of CM201-DS and CM202-DS
1. Turn OFF the power.
2. Remove the cutting cover.
3. Lubricate through the grease nipples
for the cutting unit.
[Grease : SHELL STAMINA GREASE RL2]
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
E24C-402P
E24C-403P E24C-405P
E24C-404P
E24C-406P
Grease nipples
Cutting cover
Left (Two locations) Right (One location)

Page 1-72
Check Every 560 Hours (Once a Month)
1-5-3 How to Check the Setting of the Blow Pressure
1. Press
Machine
adjust
.
• The “Machine adjustment menu” screen
appears.
2. Press Output check .
• The “Output check” screen appears.
3. Select the operation position (the
table with the transfer head of which
the vacuum pressure is to be mea-
sured).
To the next page
444C-E-MMA01-A09-07
Tools Required time 5 minutes
444C-EEn-MaOc-015

Page 1-73
REGULAR
MAINTENANCE
1
444C-E-MMA01-A09-05
Check Every 560 Hours (Once a Month)
4. Press
UNLOCK
+ .
• The display turns to be ON, and the air flows
into the pass.
∗ Ensure that the air is jetting from the tip of the
nozzle.
5. Release the lock of the A valve and
adjust the indicating pointer of the B
regulator graduation to within the
indicating range.
• The adjustment value is 0.04 MPa ± 0.005
MPa.
∗ Adjust it with the air jetting.
6. Press
UNLOCK
+ .
• The display changes to OFF.
Air blow
OFF
Air blow
ON
444C-491P
B
A