1 Introduction User manual SIPLACE D4i
1.1 Machine description From software version SR.605.03 SP2 10/2012 EN edition
16
downward compatible and therefore may also be used for the previous version of the ma-
chine. 1
Second level reel holder
When using a maximum set-up of 3 x 8 mm feeder modules, the tape reels may be restrained
in the base container and impede the handling of the tape reels. The second level reel holder
allows to swap tape reels which are restrained in the base container to the second level reel
holder and thus to ease the handling. The elevated arrangement of the second level reel
holder improves the ergonomics when setting-up and refilling components. 1
CO camera, type 30
The CO camera, type 30, replaces the CO cameras, type 29 and type 38. It allows to optically
center 0201 components as well as 01005 components. 1
Machine protection
The protective cover was redesigned. The central ridge of the previous D series machines is
removed. When the protective covers are open, unrestricted access to the inside of the ma-
chine is possible. 1
User manual SIPLACE D4i 1 Introduction
From software version SR.605.03 SP2 10/2012 EN edition 1.1 Machine description
17
1.1.4 Serial number of the machine
The serial number of the machine is punched in the rating plate (see item 1). The rating plate is
fixed to the outside of location 1 (see item 2).
1
Fig. 1.1 - 2 Serial number of the machine
(1) Rating plate
(2) Position of the rating plate on the machine
1 Introduction User manual SIPLACE D4i
1.1 Machine description From software version SR.605.03 SP2 10/2012 EN edition
18
1.1.5 EU Declaration of Conformity
The product/device described below 1
Product: Placement machine
Type: SIPLACE D4i
Item no.: 00119880 1
manufactured by
ASM Assembly Systems GmbH & Co. KG
Rupert-Mayer-Str. 44
81379 München 1
conforms to the regulations and standards listed in the EU Declaration of Conformity provided.
1.1.6 Use as prescribed
The product must only be used for its intended purposes as described in the catalogs and techni-
cal descriptions, namely the placement of SMD components, and only with the third-party equip-
ment and components recommended or permitted by ASM Assembly Systems GmbH & Co. KG
(ASM AS). Use for a different or extended purpose is not prescribed.
If the product is not used as prescribed, ASM Assembly Systems GmbH & Co. KG accepts no
liability for any damage that may occur and does not guarantee that the components will work
properly and without problems.
Use as prescribed also includes compliance with all the instructions in the user manual.
For the product to operate correctly and reliably, it must have been transported, stored, erected
and assembled correctly and must be operated and maintained with care.
1.1.7 Failure to use the product as prescribed
Failure to use the product as prescribed can result in both danger to life and limb and material
damage. For this reason any use that is not prescribed is not allowed. If the product is not used
as prescribed, ASM Assembly Systems GmbH & Co. KG accepts no liability for any damage that
may occur and does not guarantee that the components will work properly and without problems.
Use of the machine other than as prescribed includes, for example
operation of the placement machine with safety equipment deactivated or removed.
placement of components that do not meet the permitted specification.
use of component feeder modules that have not been approved.
use of unauthorized accessories and additional modules.
use of the placement machine by unqualified personnel.
operation of the placement machine without a guard ("dummy feeder") if not every location