00197295-01_UM_D4i_SR605_EN - 第191页

User manual SIPLACE D4i 5 Tasks for the operating personnel From software version SR.605.03 SP2 10/2012 EN edition 5.2 Controls and displays 191 5.2 Controls and displays 5.2.1 Position 5 Fig. 5.2 - 1 Controls and displa…

100%1 / 256
5 Tasks for the operating personnel User manual SIPLACE D4i
5.1 Personnel profile From software version SR.605.03 SP2 10/2012 EN edition
190
5.1.3.2 Tasks
The service personnel's duties include:
Major preventive maintenance jobs
Mounting replacement parts
Editing machine data
Calibrating the machine
5.1.4 Operator level "Programmer"
5.1.4.1 Training courses
A list of training courses can be found in Section 1.3, page 22.
5.1.4.2 Tasks
The programmer's jobs are as follows:
Preparing CAD files
Creating and calibrating vision data (teaching)
Writing placement programs
Implementing a new job
Data maintenance
Data backup
User manual SIPLACE D4i 5 Tasks for the operating personnel
From software version SR.605.03 SP2 10/2012 EN edition 5.2 Controls and displays
191
5.2 Controls and displays
5.2.1 Position
5
Fig. 5.2 - 1 Controls and displays
(1) Operator panel on the power supply side (7) LCD touchscreen
(2) Main power switch (8) EMERGENCY STOP button
(3) Stop button (black) (9) Indicator lamps
(4) Start button (white) (10) Button for raising the CO table
(beneath the cover flap)
(5) Component counter
(6) Keyboard
5 Tasks for the operating personnel User manual SIPLACE D4i
5.2 Controls and displays From software version SR.605.03 SP2 10/2012 EN edition
192
5.2.2 Description
All the controls can be reached by a 1.40 m tall person.
Main power switch 5
The main power switch is used to switch the power supply to the machine on and off.
WARNING
Some parts inside the machine carry potentially lethal voltages - even when switched off at the
main power switch. 5
Stop button 5
This button is used to stop the machine.
Start button 5
This button starts the machine after it has been switched on or after faults have been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
Component counter 5
The component counter displays the number of components processed in increments of ten.
LCD touchscreen 5
There is a flat screen on either side of the machine.
Keyboard 5
The keyboard is located beneath the monitor.
Indicator lamps 5
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal