00197295-01_UM_D4i_SR605_EN - 第210页

5 Tasks for the operating personnel User manual SIPLACE D4i 5.10 Docking the component trolley in or out From software version SR.605.03 SP2 10/2012 EN edition 210 5.10 Docking the component trolley in or out WA R N IN G…

100%1 / 256
User manual SIPLACE D4i 5 Tasks for the operating personnel
From software version SR.605.03 SP2 10/2012 EN edition 5.9 Refilling components
209
5.9 Refilling components
The online help contains information on refilling components with and without barcodes.
With tape feeder modules, make sure that you always splice on a new tape early enough so
that the feeder modules do not run out of components.
However, do not splice the tapes too early because if you wind the tape onto the new reel
after splicing the end of the old tape, the reel with the new tape may be overfilled. The tape
could then slip off the reel and become tangled. Under certain circumstances, this could
cause pick-up errors and prolonged down times.
Always insert spindles when using tape reels of 15" (381 mm) and larger (see Fig. 5.5 - 3
,
page 202
) and make sure that the separating plates are inserted correctly (see Fig. 5.5 - 2,
page 201
).
5 Tasks for the operating personnel User manual SIPLACE D4i
5.10 Docking the component trolley in or out From software version SR.605.03 SP2 10/2012 EN edition
210
5.10 Docking the component trolley in or out
WARNING 5
Please follow the safety instructions for docking the component trolley in and out described
in Section 2.5.2, page 52.
5.10.1 Docking out the component trolley
Click on the STOP PROCESSING PCB icon in the MAIN VIEW menu.
The PCB in progress will be completed. The icons of the single functions menu will then be
activated. 5
Click on the desired icon SINGLE FUNCTIONS GANTRY.
Select GANTRY FUNCTIONS.
From this menu, click on the GO TO SET-UP POSITION button.
All the placement heads will move across the PCB conveyor to prevent them being damaged
when the component trolley is changed. 5
Open the protective cover of the selected gantry.
Open the cover over the button for the lifting mechanism for the component table bed (see
Fig. 5.10 - 1
, item 1, page 211).
WARNING DANGER OF CRUSHING 5
When raising the component table bed, never reach into the gap between the feeders and
the used tape channel. 5
Turn the switch on the component table (item 4 in Fig. 5.10 - 1
, page 211) up.
Press the button (item 1 in Fig. 5.10 - 1
, page 211) until the component table bed (item 3 in
Fig. 5.10 - 1
, page 211) has reached the upper final position.
Unplug the supply cable of the component trolley from the socket on the station (item 2 in Fig.
5.10 - 1
, page 211).
User manual SIPLACE D4i 5 Tasks for the operating personnel
From software version SR.605.03 SP2 10/2012 EN edition 5.10 Docking the component trolley in or out
211
Fig. 5.10 - 1 Docking the component trolley in or out
5
(1) Button for raising the component table bed (beneath the cover flap)
(2) Plug for connecting the component trolley cable
(3) Component table bed, can be raised or lowered
(4) Switch for lowering the component table bed
(5) CO trolley handle
(6) Centering hole for the centering pins
(7) Supporting surface for the component table bed (right and left)
(8) Centering pin for the component table bed