User manual SIPLACE D4i 6 Station extensions From software version SR.605.03 SP2 10/2012 EN edition 6.1 Nozzle changer for the 12-nozzle Collect & Place head 217 6.1.3 Position of the nozzle changers for the C&P1…

100%1 / 256
6 Station extensions User manual SIPLACE D4i
6.1 Nozzle changer for the 12-nozzle Collect&Place head From software version SR.605.03 SP2 10/2012 EN edition
216
6.1.1 Description
This nozzle changer can hold up to 5 magazines, each with 12 nozzle holders. The magazines
are seated on a common carrier (see Fig. 6.1 - 1
, page 215). They are centered using two parallel
pins and fixed in place with clips.
A second nozzle changer can be optionally installed at each location (see item 6 in Fig. 6.1 - 2
,
page 217
).
6.1.2 Technical data
6
Nozzle changer for the 12-nozzle Collect&Place head
Dimensions (length x width x height) 472.5 x 63 x 77 mm³
Number of magazines 5, each with 12 nozzle holders
Nozzle types 9xx
Nozzle changeover time approx. 2s per nozzle
Compressed air connection 0.48 MPa (4.8 bar)
User manual SIPLACE D4i 6 Station extensions
From software version SR.605.03 SP2 10/2012 EN edition 6.1 Nozzle changer for the 12-nozzle Collect&Place head
217
6.1.3 Position of the nozzle changers for the C&P12 head
At locations 1 to 4, two nozzle changers can be installed at each location for the 12-nozzle
Collect&Place head (item 1 and 6 in Fig. 6.1 - 2
). This gives a total capacity of 8 nozzle changers
with 40 magazines and 480 nozzle holders.
6
Fig. 6.1 - 2 Position of the nozzle changers for the 12-nozzle Collect&Place head
6
(1) Nozzle changer
(2) Nozzle magazine
(3) Reject bin for nozzles
(4) Take-off device for nozzles
(5) Reject bin for components
(6) Installation location for a second nozzle changer
6 Station extensions User manual SIPLACE D4i
6.1 Nozzle changer for the 12-nozzle Collect&Place head From software version SR.605.03 SP2 10/2012 EN edition
218
6.1.4 Assembly
Each nozzle changer (see Fig. 6.1 - 2) is fixed to the used tape channel.
6
Fig. 6.1 - 3 Assembly position
(1) Spring hook pointing toward the operator
(2) Retaining clamp pointing toward the PCB conveyor
Align the nozzle changer so that the moving spring hooks always point toward the operator,
while the retaining clamps always point toward the PCB conveyor.
6.1.5 Notes on operation
When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
PLEASE NOTE 6
Fill the magazines off the machine and always replace complete magazines. 6
Open the locking plate and place the nozzles in the nozzle holders.
Close the locking plate so that the nozzles cannot drop out of the magazines.