2 Operational safety User manual SIPLACE D4i 2.9 Energy state of the machine after switching off at the main po wer switch From software version SR.605.03 SP2 10/2012 EN editi on 78 2 Fig. 2.9 - 1 Power supply unit, fron…

User manual SIPLACE D4i 2 Operational safety
From software version SR.605.03 SP2 10/2012 EN edition 2.9 Energy state of the machine after switching off at the main power switch
77
2.9 Energy state of the machine after switching off at
the main power switch
2
WARNING
The machine is supplied with 3 x 200 VAC, 3 x 208 VAC, 3 x 230 VAC, 3 x 380 VAC, 3 x 400 VAC
or 3x415VAC ± 5%, 50/60Hz main power voltage. This means that some parts of the system
carry potentially lethal voltages - even when switched off at the main power switch. Incorrect han-
dling of the machine can therefore result in death or severe injury or considerable damage to
equipment. 2
→ Always follow the applicable accident prevention and DIN regulations (particularly DIN
EN 60 204, part 1).
→ The guard over the power supply unit must ONLY be opened by appropriately qualified and
trained personnel.
2.9.1 Machine switched off at the main switch, but still connected
WARNING
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
– Infeed terminals X100 (item 2 in Fig. 2.9 - 1
, page 78)
– Discharge reactor Z2 (item 4 in Fig. 2.9 - 1
)
– Fuses FU, FV, FW and FBU (item 1 in Fig. 2.9 - 1
)
– Line filter Z1 (item 5 in Fig. 2.9 - 1
)
– Service socket BU1 (item 3 in Fig. 2.9 - 1
)
– Cable connection terminals 1, 3, and 5 of the S1 main power switch (item 6 in Fig. 2.9 - 1
)
– The color of all individual wires, which still carry potentially lethal voltages even if the main
power switch is switched off, is brown.
– Axis unit

2 Operational safety User manual SIPLACE D4i
2.9 Energy state of the machine after switching off at the main power switch From software version SR.605.03 SP2 10/2012 EN edition
78
2
Fig. 2.9 - 1 Power supply unit, front view
(1) Fuses FU, FV, FW (discharge reactor Z2) and FBU (service socket BU1)
(2) Infeed terminals X100
(3) BU1 service socket
(4) Discharge reactor Z2
(5) Line filter Z1
(6) Main power switch S1

User manual SIPLACE D4i 2 Operational safety
From software version SR.605.03 SP2 10/2012 EN edition 2.9 Energy state of the machine after switching off at the main power switch
79
The following table specifies the voltages of modules when the machine is switched off at the main
switch, but still connected to the mains supply.
2
2.9.2 Machine switched off at the main power switch and disconnected
The machine is unpowered, apart from slight residual voltages in the power supply unit.
2.9.3 Compressed air conditions in the machine after switching off at the main
power switch
When the system is switched off at the main power switch (item 1 in Fig. 2.9 - 1) or if the power
supply fails, the electrically-controlled main valve Y1 of the compressed air unit closes (item 1 in
Fig. 2.8 - 1
). The pressure will drop to 0 MPa (0 bar) within 5 seconds.
Module Voltage
Infeed terminals X100
Discharge reactor Z2
Fuses FU, FV, FW
Line filter Z1: terminals L1, L2, L3, L1’, L2’, L3’
3 x 200 VAC
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Service socket BU1
Fuse FBU
115 VAC
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Main power switch S1
Terminals 1, 3, 5
3 x 200 VAC
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Main power switch S1
Terminals 2, 4, 6 0 VAC
Power supply unit (see Fig. 2.9 - 1
)
Pin X14 (200V)
Pin X15 (GND)
Terminal P150 measured to X15
< 60 VDC
< 60 VDC
within 4 s
within 1 s