00197295-01_UM_D4i_SR605_EN - 第99页

User manual SIPLACE D4i 3 Technical data for the machine From software version SR.605.03 SP2 10/2012 EN edition 3.5 Placement head 99 3.5.1.3 Operation with a vacuum pump The 12-nozzle Co llect&Place head can be conv…

100%1 / 256
3 Technical data for the machine User manual SIPLACE D4i
3.5 Placement head From software version SR.605.03 SP2 10/2012 EN edition
98
then set down gently and accurately on the PCB with a blast of air. The twelve nozzles on
SIPLACE Collect&Place heads turn about a horizontal axis, in contrast to conventional chip
shooters. This does not simply save space: the small diameter means that substantially smaller
centrifugal forces occur in comparison to conventional chip shooters. This largely eliminates the
risk of components slipping during transportation.
And there is yet another benefit: the cycle time of the Collect&Place head is the same for all com-
ponents, which means that the placement rate is not dependent on the component size.
3.5.1.2 Technical data
3
12-nozzle Collect&Place head with
CO camera type 28,
18 x 18, digital
(see Section 3.8.1
, page 116)
12-nozzle Collect&Place head with
CO camera type 30,
27 x 27, digital
(see Section 6.9
, page 237)
Range of components
a
0402 to PLCC44, BGA, BGA, flip-
chip, TSOP, QFP, SO to SO32,
DRAM
01005
b
to flip-chip, bare die,
PLCC44, BGA, *BGA, TSOP, QFP,
SO to SO32, DRAM
Component specification
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
6 mm
0.5 mm
0.2 mm
0.35 mm
0.2 mm
1.0 x 0.5 mm²
18.7 x 18.7 mm²
2 g
6 mm
0.3 mm
0.15 mm
0.25 mm
0.14 mm
0.4 x 0.2 mm²
18.7 x 18.7 mm²
2 g
Programmed power stage
1
2
3
4
5
Programmed set-down force [N]
2.4 ± 0.5
2.4 ± 0.5
3 + 1
4 + 1
5 + 1
User manual SIPLACE D4i 3 Technical data for the machine
From software version SR.605.03 SP2 10/2012 EN edition 3.5 Placement head
99
3.5.1.3 Operation with a vacuum pump
The 12-nozzle Collect&Place head can be converted for operation with a vacuum pump for more
efficient vacuum generation (see Section 6.12
, page 239).
Nozzle types 9xx 9xx
X/Y accuracy
c
± 50 m/3, ± 67 m/4 ± 50 m/3± 67 m/4
Angular accuracy ± 0.53°/3, ± 0.71°/4 ± 0.53°/3, ± 0.71°/4
Component range 98% 98.5%
Component camera type 28 30
Illumination levels 5 5
Possible illumination level set-
ting
256
5
256
5
a) Please note that the component range that can be placed is also affected by the pad geometry, the cus-
tomer-specific standards and the packaging tolerances.
b) With 01005 package
c) The accuracy value was measured using the vendor-neutral IPC standard
3 Technical data for the machine User manual SIPLACE D4i
3.6 Gantry system From software version SR.605.03 SP2 10/2012 EN edition
100
3.6 Gantry system
3.6.1 Position of the gantries
3
Fig. 3.6 - 1 Position of the gantries
(1) Gantry 1
(2) Gantry 2
(3) Gantry 3
(4) Gantry 4
The gantry system consists of two functional groups
–X axis and
–Y axis
Placement area 2
Placement area 1