3-3 Tg1357-ID-SO 0703-003 3.2 Uninstallation Procedure for Flux Dispensing Unit C A U T I O N Do not drop any flux dispensing unit during the attachment or detachment. Otherwise, a foot injury will result or some feeders …

3-2
Tg1357-ID-SO
0703-003
3.1 Installation Procedure for Flux Dispensing Unit
CAUTION
Do not drop any flux dispensing unit during the attachment or
detachment. Otherwise, a foot injury will result or some feeders may be
damaged.
Carefully handle each unit one by one and do not drop any.
Notice
(a) If the flux dispensing unit is seated afloat, the machine
(GXH Series) may be damaged or pickup errors will be
caused.
Be sure to install the unit correctly on the feeder base.
(b) Keep the unused flux dispensing unit uninstalled from the
bank feeder change cart.
If a flux dispensing unit is kept used for a long period of
time, the flux is hardened. Using such a unit will cause
defective components.
Procedure
(1) Before installing a flux dispensing unit, confirm that no foreign
substances (dirt or dust) are found on the feeder base located on the
upper area of the cart.
(2) Install the flux dispensing unit on the specified feeder No. position.
Notice
Do not select a wrong feeder No. position. Otherwise, some
components may be trapped in the drum (rotational disk) area.
(3) Grasp the grip and insert the end of the flux dispensing unit so that the
end can be aligned correctly with the rails of the feeder base.
At this time, ensure that the unit is securely installed by pushing the
rear side of the grip forward.
Notice
Be sure to install the flux dispensing unit securely on the rails
of the feeder base.
(4) Push the grip and slowly insert the unit forward until it makes a "click"
sound. At this time, confirm that the connectors of the flux dispensing
unit are securely connected.
3.1 Installation Procedure for Flux Dispensing Unit

3-3
Tg1357-ID-SO
0703-003
3.2 Uninstallation Procedure for Flux Dispensing Unit
CAUTION
Do not drop any flux dispensing unit during the attachment or
detachment. Otherwise, a foot injury will result or some feeders may be
damaged.
Carefully handle each unit one by one and do not drop any.
Procedure
(1) Push the clamping release lever.
(2) Slowly bring forward the flux dispensing unit.
3.2 Uninstallation Procedure for Flux Dispensing Unit

3-4
Tg1357-ID-SO
0703-003
3.3 Procedure for Syringe Replacement
The following describes how to replace a syringe with another one.
WARNING
Take as much care as possible not to allow flux on your skin
and wear protective gear, including gloves and mask when
necessary.
If by mistake you directly touch or drink it, it might so adversely
affect you as to harm you.
CAUTION
Flux is inflammable, so do not bring it close to any fire when
handling.
Procedure
(1) Detach the needle from the cylinder end.
Cylinder
Needle
Fig. 11
Notice
The needle is screwed into the end. Be sure not to pull it
out from the end.
3.3 Procedure for Syringe Replacement