OM-1606-006w_GT-28x.pdf - 第223页
OM-1606 1 1-2 1 1. T roubleshooting Remedy : Remove any chip component or foreign substance such as debris attached on the suppressor and completely clean the suppressor . If the taping component is mounted with any fore…

OM-1606
11-1
11. Troubleshooting
11. Troubleshooting
The main troubleshooting during the tape feeder operation is described here.
In the event of trouble, con rm in which section the trouble is caused and set it
right.
11.1 Component Pick-up Error
Remedy
: Align the chip component center with the marks on the suppressor according to "5.
Component Pick-up Position Alignment".
Marks on the Suppressor
If the component center is not aligned with the pick-up position, then the pick-up cannot
proceed correctly.
Cause : Inappropriate pick-up positioning
Notice
Remedy
: Adjust the pick-up position by using the feeder adjusting jig JG-0209
(Purchase separately).
Pick-up Position
If the component center is not aligned with the pick-up position, then the pick-up cannot
proceed correctly.
Cause : Error in Pick-up Position
Notice
0908-001

OM-1606
11-2
11. Troubleshooting
Remedy
: Remove any chip component or foreign substance such as debris attached on the
suppressor and completely clean the suppressor.
If the taping component is mounted with any foreign substance attached, the suppresser
might be deformed or a pick-up error occur.
Therefore, clean it.
Cause : Chip component has become attached inside the suppressor and
moves wild.
Chip component or foreign
substances including debris
Notice
1005-002
Remedy
: Clean the vacuum nozzle on the main machine of SIGMA-G4/G5 according to
"Volume 4: Maintenance and Troubleshooting" in the Instruction Manual for
SIGMA-G4/G5 main machine.
If the factory is dusty or if paper taping component is often used, then the vacuum nozzle and vacuum
nozzle lter can easily become dirty.
Keep them clean.
Cause : Dirty Vacuum Nozzle
Clogged Vacuum Nozzle Hole
Dirty Vacuum Nozzle Filter
Note

OM-1606
11-3
11. Troubleshooting
0908-001
11.2 Tape Feeder not correctly locked
Remedy
: Remove any chip component or foreign substance such as debris attached on the
feeder base and completely clean the feeder base.
If the tape feeder is used while it has not been locked, it might cause damage to the machine or pick-
up error.
Attach the tape feeder securely to the feeder base.
Cause : Chip component or foreign substances including debris have been
attached onto the feeder base.
Note