3. Setup 3 - 55 Standard specifications No. Abbrev. Parameter name Explanation F E D C B A 9 8 7 6 5 4 3 2 1 0 pen ent mtyp bit Explanation 0 Set the motor type. 1 2 Setting 0x 1x 2x 3x 4x 5x 6x 7x 3 x0 HA40N HA50L HA53L…

3. Setup
3 - 54
Standard specifications
No. Abbrev. Parameter name Explanation
Setting range
(Unit)
In the case of the semi-closed loop control
Set the same value as SV020 (RNG2). (Refer to the explanation of
SV020.)
1 to 9999
(kp/rev)
In the case of the full-closed loop control
Set the number of pulses per ball screw pitch.
Detector model name Resolution SV019 setting
O H E 2 5 K -E T , O H A2 5 K - E T 100,000 (p/rev) 100
OSE104-ET,OSA104-ET 100,000 (p/rev) 100
OSE105-ET,OSA105-ET 1,000,000 (p/rev) 1000
Relative position
detection scale
Refer to detector
specification ma nual
PIT/Resolution
(
µm)
AT41 (Mitsutoyo) 1 (µm/p)
The same as
SV018 (PIT)
AT342 (Mitsutoyo) 0.5 (µm/p)
Twice as big as
SV018 (PIT)
FME type, FLE type
(Futaba)
Refer to detector
specification ma nual
PIT/Resolution
(
µm)
MP type (Mitsubishi
Heavy Industries)
Refer to detector
specification ma nual
PIT/Resolution
(
µm)
SV019 RNG1*
Position detector
resolution
1 to 9999
(kp/pit)
Set the number of pulses per one revolution of the motor end detector.
Detector model name SV020 setting
OSE104, OSA104 100
OSE105, OSA105 1000
SV020 RNG2*
Speed detector
resolution
1 to 9999
(kp/rev)
SV021 OLT
Overload detection
time constant
Set the detection time constant of Overload 1 (Alarm 50).
Set to “60” as a standard. (For machine tool builder adjustment.)
1 to 999
(s)
SV022 OLL
Overload detection
level
Set the current detection level of Overload 1 (Alarm 50) in respect to the
stall (rated) current.
Set to “150” as a standard. (For machine tool builder adjustment.)
110 to 500
(Stall [rated]
current %)
Set the excessive error detection width when servo ON.
Rapid traverse rate
(mm/min)
<Standard
setting value>
OD1=OD2=
60
× PGN1
÷ 2 (mm)
SV023 OD1
Excessive error
detection width
during servo ON
When “0” is set, the excessive error detection will not be performed.
0 to 32767
(mm)
SV024 INP
In-position
detection width
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning accuracy gets, however,
the cycle time (setting time) becomes longer. The standard setting is “50”.
0 to 32767
(µm)
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.

3. Setup
3 - 55
Standard specifications
No. Abbrev. Parameter name Explanation
F E D C B A 9 8 7 6 5 4 3 2 1 0
pen ent mtyp
bit Explanation
0 Set the motor type.
1
2 Setting 0x 1x 2x 3x 4x 5x 6x 7x
3 x0 HA40N HA50L HA53L
4
mtyp
x1 HA80N HA100L HA103L
5 x2 HA100N HA200L HA203L
6 x3 HA200N HA300L HA303L
7 x4 HA300N HA500L HA503L
x5 HA700N
x6 HA900N
x7 HA-LH11K2
x8 HA-LH15K2
x9
xA HA150L HA153L
xB
xC
xD
xE
xF
Setting 8x 9x Ax Bx Cx Dx Ex Fx
x0 HA43N HC52 H53
x1 HA83N HC102 HC103 HC103R
x2 HA103N HC152 HC153 HC153R
x3 HA203N HC202 HC203 HC203R
x4 HA303N HC352 HC353 HC353R
x5 HA703N HC452 HC453 HC503R
x6 HC702 HC703
x7 HC902
x8
x9
xA HA93N
xB
xC HA053N
xD HA13N
xE HA23N
xF HA33N
SV025 MTYP*
Motor/Detector
type
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.

3. Setup
3 - 56
Standard specifications
No. Abbrev. Parameter name Explanation
Setting range
(Unit)
bit Explanation
8
9
A
ent
B
Set the detector type.
Set the position detector type for “pen”, and the speed detector type
for “ent”. In the case of the semi-closed loop control, set the same
value for “pen” and “ent”.
C Detector model name pen setting ent setting
D OSE104 0 (Note) 0
E
pen
OSA104 1 (Note) 1
F OSE105, OSA105 2 (Note) 2
3 (Note) 3
OHE25K-ET, OSE104-ET 4 Setting impossible
OHA25K-ET, OSA104-ET 5 Setting impossible
OSE105-ET, OSA105-ET 6 Setting impossible
7 Setting impossible
Relative position detection
scale, MP type (Mitsubishi
Heavy Industries)
8 Setting impossible
AT41 (Mitsutoyo), FME type,
FLE type (Futaba)
9 Setting impossible
AT342 (Mitsutoyo) A Setting impossible
B Setting impossible
The setting of the slave axis in
the speed/current
synchronization control.
When the master axis is the
semi-closed control .
C
C
(Current
synchronization)
D Setting impossible
E Setting impossible
F Setting impossible
(Note) Setting for semi-closed loop control
SV025 MTYP*
Motor/Detector
type
SV026 OD2
Excessive error
detection width
during servo OFF
Set the excessive error detection width when servo ON.
For the standard setting, refer to the explanation of SV023 (OD1).
When “0” is set, the excessive error detection will not be performed.
0 to 32767
(mm)
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.