bnp-b2365(eng)b.pdf - 第145页
3. Setup 3 - 58 Standard specifications No. Abbrev. Parameter name Explanation S etting range (Unit) Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid…

3. Setup
3 - 57
Standard specifications
No. Abbrev. Parameter name Explanation
Setting range
(Unit)
F E D C B A 9 8 7 6 5 4 3 2 1 0
aflt zrn2 afse ovs lmc zrn3 vfct upc vcnt
bit Meaning when “0” is set Meaning when “1” is set
0
1
vcnt
Set the execution changeover type of the speed loop delay compensation.
00: Delay compensation changeover invalid
10: Delay compensation type 2
01: Delay compensation changeover type 1
11: Setting prohibited
2 upc Starting torque compensation invalid Starting torque compensation valid
3
4
5
vfct
Set the number of compensation pulses of the jitter compensation.
00: Jitter compensa tion invalid
10: Jitter compensation 2 pulse s
01: Jitter compensation 1 pulse
11: Jitter compensation 3 pulses
6zrn3
ABZ scale: Set to "1" to fix Z-phase detection edge.
Absolute position scale: Set to "1" in using AT342.
7 omr Machine end compensation invalid Machine end compensation valid
8
9
lmc
Set the compensation amount w ith SV016 (LMC1) and SV041 (LMC2).
00: Lost motion compensation stop
10: Lost motion compensation type 2
01: Lost motion compensation ty pe 1
11: Setting prohibited
A
B
ovs
Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).
00: Overshooting compensation stop
10: Overshooting compensation ty pe 2
01: Overshooting compensation ty pe 1
11: Setting prohibited
C 00: Adaptive filter sensitivity standard
D
afse
11: Adaptive filter sensitivity increase (Set 2bits at a time)
E zrn2 Set to “1”.
F aflt Adaptive filter stop Adaptive filter start
SV027 SSF1
Servo function
selection 1
(Note) Set to "0" for bits with no particular description.
SV028
Not used. Set to "0". 0
SV029 VCS
Speed at the
change of speed
loop gain
If the noise is bothersome at high speed during rapid traverse, etc, lower
the speed loop gain.
Set the speed at which the speed loop gain changes, and use this with
SV006 (VGN2).
When not using, set to “0”.
0 to 9999
(r/min)
The higher order 8bits and lower order 8bits are used for different functions.
“The setting value of SV030” = (Icx × 256) + IVC
Abbrev. Parameter name Explanation
Setting range
(Unit)
IVC
(Low
order)
Voltage dead band
compensation
When 100% is set, the voltage equivalent to the logical
non-energized time will be compensated.
When “0” is set, a 100% compensation will be performed.
Adjust in increments of 10% from the default value 100%.
If increased too much, vibration or vibration noise may be
generated.
0 to 255
(%)
Icx
(High
order)
Current bias 1
Normally set to “0”.
Use this in combination with SV040 and the high order
8bits of SV045.
0 to 127
SV030
0 to 32767
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.

3. Setup
3 - 58
Standard specifications
No. Abbrev. Parameter name Explanation
S
etting range
(Unit)
Set this if overshooting occurs during positioning. This compensates the
motor torque during positioning.
This is valid only when the overshooting compensation SV027 (SSF1.ovs)
is selected.
Type 1: When SV027 (SSF1)/bitB, A (ovs)=01
Set the compensation amount based on the motor’s stall current.
This compensates overshooting that occurs during pulse feeding.
Normally, use Type 2.
Type 2: When SV027 (SSF1)/bitB, A (ovs)=10
Set the compensation amount based on the motor’s stall current.
Increase by 1% and determine the amount that overshooting doesn’t
occur.
In Type 2, compensation during the feed forward control during circular
cutting won’t be performed.
Type 3: When SV027 (SSF1)/bitB, A (ovs)=11
Use this to perform the overshooting compensation during circular
cutting or the feed forward control. The setting method is the same in
Type 2.
SV031 OVS1
Overshooting
compensation 1
When you wish different compensation amount depending on the direction
When SV042 (OVS2) is “0”, compensate with the value of SV031
(OVS1) in both of the + and -directions.
If you wish to change the compensation amount depending on the
command direction, set this and SV042 (OVS2). (SV031: + direction,
SV042: - direction. However, the directions may be opposite
depending on other settings.)
When “-1” is set, the compensation won’t be performed in the direction of
the command.
-1 to 100
(Stall [rated]
current %)
SV032 TOF
Torque offset
Set the unbalance torque of vertical axis and inclined axis. -100 to 100
(Stall [rated]
current %)
FEDCBA98765 4 3 2 10
hvx svx fhz2 nfd1 zck
bit Meaning when “0” is set Meaning when “1” is set
0 zck Z phase check valid (Alarm 42) Z phase check invalid
1 S et the filter depth for Notch filter 1 (SV038).
2 nfd1 Value 000 001 010 011 100 101 110 111
3
Depth (dB)
DeepÅ
Infntly
deep
-18.1 -12.0 -8.5 -6.0 -4.1 -2.5 -1.2
ShallowÆ
4
5
6fhz2
7
Set the operation frequency of Not ch filter 2
0: Invalid 3: 750Hz 6: 375Hz
1: 2250Hz 4: 563Hz 7: 321Hz
2 : 1125Hz 5: 450Hz 8 to F: 281Hz
8 svx
Set the performance mode of the servo control. (Only for
MDS-C1-Vx)
9hvx
00: By current loop gain
01: MDS-B-Vx compatible mode
selected
10: High gain mode selected
11: High gain mode selected
A
B
C
D
E
F
SV033 SSF2
Servo function
selection 2
(Note) Set to “0” for bits with no particular description.
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.

3. Setup
3 - 59
Standard specifications
No. Abbrev. Parameter name Explanation
S
etting range
(Unit)
FEDCBA98765 4 3 2 10
ovsn has2 has1
bit Meaning when “0” is set Meaning when “1” is set
0 has1
Setting for normal use.
(Except for HC)
HAS control 1 valid
(HC: High acceleration rate support)
1 has2
Setting for normal use.
(Except for HC)
HAS control 2 valid
(HC: Overshooting support)
2
3
4
5
6
7
8
9
A
B
C
D
E
ovsn
F
Set the non-sensitive band of the overshooting compensation type 3 in
increments of 2m at a time.
In the feed forward control, the non-sensitive band of the model
position droop is set, and overshooting of the model is ignored. Set
2µm (0001) as a standard.
SV034 SSF3
Servo function
selection 3
(Note) Set to “0” for bits with no particular description.
HEX setting
FEDCBA98765 4 3 2 10
clt clG1 cl2n clet cltq iup tdt
bit Meaning when “0” is set Meaning when “1” is set
0
1
2
3
4
5
tdt
Td creation time setting
Set to “0”. (For machine tool builder adjustment)
6iup
Set to “1” when using any of motors from HC152 to HC702 and from
HC153 to HC453.
7 ckab
Setting for normal use No signal 2 (Alarm 21) special
detection
8
Set the retracting torque for collision detection in respect to the
maximum torque of the motor.
9
Cltq
00: 100% 01: 90% 10: 80% (Standard) 11: 70%
Aclet
Setting for normal use The disturbance torque peak of the
latest two seconds is displayed in
MPOS of the servo monitor screen.
B cl2n Collision detection method 2 valid
Collision detection method 2
invalid
C
Collision detection method 1
Set the collision detection level during cutting feed (G1).
D clG1 The G1 collision detection level=SV060*clG1.
E
When clG1=0, the collision detection method 1 during cutting feed
won’t function.
Fclt
Setting for normal use The guide value of the SV059
setting value is displayed in MPOS
of the servo monitor screen.
SV035 SSF4
Servo function
selection 4
(Note) Set to “0” for bits with no particular description.
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.