3. Setup 3 - 73 No. Abbr. Parameter name Details <For MDS-C1-SPM> F E D C B A 98765 4 3 2 10 poff ront bit Meaning when set to 0 Meaning when set to 1 Standard 0 0 1 0 2 0 3 0 SP033 SFNC1* Spindle function 1 4 0 5 …

3. Setup
3 - 72
No. Abbr. Parameter name Details
<For MDS-C1-SP/SPH>
FEDCBA98765 4 3 2 10
poff hzs ront
pycal
pychg
pyst pyoff sftk dflt
1a2m
bit Meaning when set to 0 Meaning when set to 1 Standard
0 1a2m 1 drive unit 2 motor function: Invalid 1 drive unit 2 motor function: Valid 0
1 dflt Default motor: Main Default motor: Sub 0
2 sftk Without SF-TK card With SF-TK card 0
3 0
4 0
5 0
6pyoff 0
7pyst 0
8pychg
This is used by Mitsubishi. Set to "0" unless particularly designated.
0
9 pycal (Conventional specifications)
High-speed rate deceleration
method valid for minimum excitation
rate
0
A 0
B 0
C ront Normal ready ON High-speed ready ON 0
D 0
Ehzs
Gate OFF by high-cycle zero speed
invalid
Gate OFF by high-cycle zero speed
valid
0
F poff
Contactor hold at NC power OFF
invalid
Contactor hold at NC power OFF
valid
0
(Note 1) bits 0, 1 and 2 are invalid for SPH.
(Note 2) Set 0 if there is no particular explanation for the bit.
SP033 SFNC1* Spindle function 1
<For MDS-C1-SPX/SPHX>
FEDCBA98765 4 3 2 10
poff hzs
sfnc1
ront
pycal
pychg
pyst pyoff
bit Meaning when set to 0 Meaning when set to 1 Standard
0 0
1 0
2 0
3 0
4 0
5 0
6pyoff 0
7pyst 0
8pychg
This is used by Mitsubishi. Set to "0" unless particularly designated.
0
9 pycal (Conventional specifications)
High-speed rate deceleration
method valid for minimum excitation
rate
0
A 0
B 0
C ront Normal ready ON High-speed ready ON 0
D sfnc1 MDS-B-PJEX connection invalid MDS-B-PJEX connection valid 1
Ehzs
Gate OFF by high-cycle zero speed
invalid
Gate OFF by high-cycle zero speed
valid
0
F poff
Contactor hold at NC power OFF
invalid
Contactor hold at NC power OFF
valid
0
(Note) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.

3. Setup
3 - 73
No. Abbr. Parameter name Details
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
poff
ront
bit Meaning when set to 0 Meaning when set to 1 Standard
0 0
1 0
2 0
3 0
SP033 SFNC1* Spindle function 1
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C ront Normal ready ON High-speed ready ON 0
D 0
E 0
F poff
Contactor hold at NC power OFF
invalid
Contactor hold at NC power OFF
valid
0
(Note) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.

3. Setup
3 - 74
No. Abbr. Parameter name Details
<For MDS-C1-SP/SPH/SPX/SPHX>
FEDCBA98765 4 3 2 10
mkc2 mkch
invm mtsl
bit Meaning when set to 0 Meaning when set to 1 Standard
0 mtsl Special motor constant invalid Special motor constant setting valid 0
1invm
A general-purpose motor FV control
invalid
A general-purpose motor FV control
valid
0
2 mkch Coil switch function invalid Coil switch function valid 0
3 mkc2 Coil switch function 2 invalid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.
SP034 SFNC2* Spindle function 2
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
mkc2 mkch mk3c
mtsl
bit Meaning when set to 0 Meaning when set to 1 Standard
0 mtsl Special motor constant invalid Special motor constant setting valid 0
1 mk3c 3-step coil switch function invalid 3-step coil switch function valid 0
2 mkch Coil switch function invalid Coil switch function valid 0
3 mkc2 Coil switch function 2 invalid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.