bnp-b2365(eng)b.pdf - 第162页

3. Setup 3 - 75 No. Abbr. Parameter name Details <For MDS-C1-SP/SPH/SPX/SPHX> F E D C B A 98765 4 3 2 10 l b s d h b s d l w i d h w i d bit Meaning when set to 0 Meaning when set to 1 Standard 0h w i d H-coil wide…

100%1 / 399
3. Setup
3 - 74
No. Abbr. Parameter name Details
<For MDS-C1-SP/SPH/SPX/SPHX>
FEDCBA98765 4 3 2 10
mkc2 mkch
invm mtsl
bit Meaning when set to 0 Meaning when set to 1 Standard
0 mtsl Special motor constant invalid Special motor constant setting valid 0
1invm
A general-purpose motor FV control
invalid
A general-purpose motor FV control
valid
0
2 mkch Coil switch function invalid Coil switch function valid 0
3 mkc2 Coil switch function 2 invalid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.
SP034 SFNC2* Spindle function 2
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
mkc2 mkch mk3c
mtsl
bit Meaning when set to 0 Meaning when set to 1 Standard
0 mtsl Special motor constant invalid Special motor constant setting valid 0
1 mk3c 3-step coil switch function invalid 3-step coil switch function valid 0
2 mkch Coil switch function invalid Coil switch function valid 0
3 mkc2 Coil switch function 2 invalid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
3 - 75
No. Abbr. Parameter name Details
<For MDS-C1-SP/SPH/SPX/SPHX>
FEDCBA98765 4 3 2 10
lbsd hbsdlwidhwid
bit Meaning when set to 0 Meaning when set to 1 Standard
0hwid
H-coil wide-range constant output
invalid
H-coil wide-range constant output
valid
0
1lwid
L-coil wide-range constant output
invalid
L-coil wide-range constant output
valid
0
2 hbsd H-coil base slide invalid H-coil base slide valid 0
3 lbsd L-coil base slide invalid L-coil base slide valid 0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.
SP035 SFNC3* Spindle function 3
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
mwid
lwid hwid
bit Meaning when set to 0 Meaning when set to 1 Standard
0hwid
H coil output characteristic
change invalid
H coil output characteristic
change valid
0
1lwid
L coil output characteristic
change invalid
L coil output characteristic
change valid
0
2mwid
M coil output characteristic
change invalid
M coil output characteristic
change valid
0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
3 - 76
No. Abbr. Parameter name Details
<For MDS-C1-SP>
FEDCBA98765 4 3 2 10
dslm
dssm
enc2 enc1
mag2 mag1
plg2 plg1
bit Meaning when set to 0 Meaning when set to 1 Standard
0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 0
1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 0
2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 0
3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 0
4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 0
5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 0
6 0
7 0
8 dssm Speedometer output valid Speedometer output invalid 0
9 dslm Load meter output valid Load meter output invalid 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.
SP036 SFNC4* Spindle function 4
<For MDS-C1-SPH/SPX/SPHX/SPM>
FEDCBA98765 4 3 2 10
bit Meaning when set to 0 Meaning when set to 1 Standard
0 0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B 0
C 0
D 0
E 0
F 0
(Note) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.