HS-50 transport contr oller 2 Retrofit instructions internal C onveyor control TSP200 in machine no .: 1-20 SIPLACE HS-50 08/2000 Edition 23 2.7 Inst alling the conversion board : Connect any remaining ca bles on the old…

2 Retrofit instructions internal Conveyor control TSP200 in machine no.: 1-20 SIPLACE HS-50 HS-50 transport controller
08/2000 Edition
22
: Unplug the CAN bus cable from the old conveyor control and SLIOs and connect the cable to
the new conveyor control as follows:
Connect the last connector (X18am) to the Conveyor 1 terminal (X22ao) and connector
(x34ao) to the Conveyor 2 terminal (X22ap).
2
2
: Detach connectors X3am/X6am (or X3an/X6an on the dual conveyor) from the SLIOs and pull
them through the machine to the new conveyor control.
2

HS-50 transport controller 2 Retrofit instructions internal Conveyor control TSP200 in machine no.: 1-20 SIPLACE HS-50
08/2000 Edition
23
2.7 Installing the conversion board
: Connect any remaining cables on the old conveyor control and SLIO to the conversion board
for the relevant conveyor.
: Detach the old conveyor control.
: Detach and remove the SLIO module from the top hat rail.
: Clean around the components.
: Attach the drilling template and cover the area well.
2
: Mark the drilling positions with the prick punch.
: First drill pilot holes with a 2 mm diameter bit to prevent the holes running off center.
Then drill with a 3.4 mm bit (rather than 3.3 mm) to make the threads easier to cut.
2
IMPORTANT:
It is essential to use a thread cutter for blind holes as the material is very tenacious. 2
2
2
2
2
2

2 Retrofit instructions internal Conveyor control TSP200 in machine no.: 1-20 SIPLACE HS-50 HS-50 transport controller
08/2000 Edition
24
: Now fix the short spacer bolts and place the conversion board on them.
2
Fig. 2.7 - 1 Old and new appearance of the conveyor
2
: Pull the connecting cables from the conveyor control to the conversion board through the cable
opening.
: Shorten the high cable duct in the middle in order to fit the covers to the conversion boards in
the conveyor.
: Reinstall all the parts the you removed or detached. The cables and compressed air hoses for
the tape cutter and NC gantry 1 must be fixed over the new conveyor control using new adhe-
sive tabs and cable ties.
2.6 Loading the conveyor software
: Use the instructions for the TSP200 retrofit kit for loading the software (item no.: 00192267-01).
2