1 Introduction
1.1 Safety Instructions 1.1.2 Safety Instructions
80 SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur
chine, make sure the has been turned off at the main switch and is isolated from the line supply. In ad
-
dition, the compressed air supply must be turned off at the main valve of the compressed air unit in the
machine base and the compressed air lines must be bled by actuating the needle valve at the com
-
pressed air unit.
Danger: persons wearing a heart pacemaker are not permitted to work near linear motors, as described
in detail in the User Manual and the Service Manual, Chapter "Special Safety Instructions when working
in vicinity of powerful magnetic fields" .
Observe the applicable accident prevention regulations, DIN standards and special safety regulations
applicable for your country at all times.
Carefully read and observe the instructions about residual voltage in the Chapter "Operational Safety".
Also observe the ESD regulations in the Chapter "Operational Safety" of the operating manual.
Before performing any service or refitting work on the machine, secure it to prevent unauthorized use,
as described in the Chapter "Locking the Machine...".
There is an additional, higher risk of accident when working with the SITEST program.
The SITEST program may therefore only be started by specially authorized and trained
Put the tape feeder module on a stable, flat (!) surface, once it has been removed from the packaging.
Make sure that pressure is not applied to the sides, until the module is lying totally flat on an even sur
-
face. Otherwise, this could lead to malfunctions or irreparable damage to the feeder module, making re
-
adjustment work or even replacement necessary.
Make sure that the tape feeder module is not unintentionally trapped or clamped (e.g. in vices), otherwise
it could be squeezed or bent etc. If you need help, organize an assistant to hold it.
1.1.2.1
1.1.2.1 Definitions
Definitions
1.1.2.2
1.1.2.2 ESD Safety
ESD Safety
CAUTION
Avoid errors!
This message draws the operator's attention to possible sources of error which should be
avoided during work.
NOTICE
Useful tips!
This message draws the operator's attention to useful information which will make work easier
and help you optimize efficiency.
CAUTION
Always observe!
Warnings such as these draw the operator's attention to instructions or messages which must
be observed. Nonobservance causes a considerable risk of damage to the equipment and/or
injuries to the operator.
CAUTION
Observe the ESD regulations!
Pay attention to feeder module ESD safety:
Before you open the side cover, make sure you are wearing the ESD protection wristband, to
prevent damage to the highly sensitive boards inside the feeder module.
1 Introduction
1.2.1 Environmentally-Friendly Disposal of Materials and Components 1.2 Other Instructions
SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur 81
1.2
1.2 Other Instructions
Other Instructions
1.2.1
1.2.1 Environmentally-Friendly Disposal of Materials and Components
Environmentally-Friendly Disposal of Materials and Components
SIPLACE products are manufactured using only materials and parts that can be easily separated and
disposed of in an environmentally-friendly way.
1.2.2
1.2.2 Use of Original SIPLACE Accessories and Spare Parts
Use of Original SIPLACE Accessories and Spare Parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety and
will invalidate the liability for any consequential damage.
1.2.3
1.2.3 Information About This Service Manual
Information About This Service Manual
1.2.4
1.2.4 Release History
Release History
1.2.5
1.2.5 SIPLACE on the World Wide Web (WWW)
SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the
SIPLACE User Group
. Here you can call up spe
-
cial information about our placement systems e.g.
Technical documentation,
Technical information,
Spare parts lists etc.
Registration for the user group is very simple:
Click on the Register link.
Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.
1.3
1.3 Requirements
Requirements
To correctly repair S-Feeder modules, you require an ESD-compatible workplace with a stable, level and
clean surface.
NOTICE
Observe the applicable regulations
The company operating the system has sole responsibility for the proper, environmentally-
friendly disposal of machines, working materials, consumables and wear parts.
Please observe your national statutory provisions for waste disposal and environmental
protection.
WARNING
Additional qualifications required
The service work described in this manual may only be performed by specially trained person
-
nel and therefore requires additional qualifications and skills.
Release Changes
01/2012 First edition
04/2013 Revision, supplements
1 Introduction
1.4 Warranty 1.2.5 SIPLACE on the World Wide Web (WWW)
82 SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur
1.4
1.4 Warranty
Warranty
CAUTION
Observe the clauses in the warranty agreements for your feeder.
On the bottom right side of the tape drive, you will find a warranty seal. If you still have valid