Besi JTF2 Traystak Feeder - 第34页

Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLAC E S-25 HM / S-27 HM / HS-50 / HS-60 / HF -series / X-series 11/2006 Edition 34 2.3 Restrictions The T raystak feed er requires an operating pressur e between 4.1 …

100%1 / 60
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
33
2 Retrofit instructions: Besi JTF2
(Traystak Feeder)
2.1 Functional description of the adapter
This adapter has 2 locating pins to ensure that the Besi JTF2 feeder is always positioned in the
same place so the pick-up offsets do not have to be changed every time a feeder is fitted. 2
The feeder can be fitted to / removed from the component trolley together with the adapter. 2
2.2 Requirements
2
Adapter (supplied as standard with the JTF2) 2
Drilling template (supplied as standard with the JTF2) 2
Besi Traystak feeder 2
2
2
2
Software
SIPLACE Pro 2.1 or later
Station from 505.02
Hardware:
Siemens SIPLACE special design for tape guide channels for S, HS, HF or X machines
S-2X HM 00176028-xx 1 x JTF2
00176029-xx 2 x JTF2
HF-series / X-series 00176032-xx 1 x JTF2
00176033-xx 2 x JTF2
HS-xx 00176036-xx 1 x JTF2 and 2 x JTF2
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
34
2.3 Restrictions
The Traystak feeder requires an operating pressure between 4.1 and 9.0 bar. 2
If the Traystak feeder is connected to the compressed air supply for the component trolley on the
placement machine (or to the compressed air connection for the bulk case feeder on the compo-
nent trolley), it is no longer possible to use a bulkcase feeder on that component trolley. 2
A compressed air branch cannot be used either, since the Traystak feeder requires a higher pres-
sure than the bulk case feeder. 2
If a head crash guard is attached (feeder cover flap), it must be removed. 2
Tape feeders may not be inserted in positions without tape guide channel. 2
The handles of the component trolley cannot be folded up on the S-2X HM and HS-XX in order to
push or pull the trolley. 2
2.3.1 SIPLACE S-25 HM / S-27 HM
Up to three Traystak feeders may be used per component table (up to 6 per S-27 HM). 2
If the Traystak feeder is used, it may not be possible to open the machine's safety doors when the
feeder is in certain positions. 2
If you are using 2
one JTF: the tape guide channel must be removed or shortened.
two JTFs: the tape guide channel must be removed or shortened.
three JTFs: the tape guide channel must be removed entirely.
It is not possible to use a nozzle changer.
2.3.2 SIPLACE HS-series / HF-series / X-series
One or two Traystak feeders may be used per component table. 2
The Traystak feeder can only be used at locations 2 and 4. 2
The nozzle changer, tape guide channel and nozzle reject bin can only be used under certain cir-
cumstances. 2
If two Traystak feeders are set up on a HF-series / X-series, segment two of the Twinhead can
only pick up components from left hand Traystak feeder under certain circumstances. 2
For HS-series it is not possible to place the Traystak feeder in the center of the component trolley
by screwing. 2
For X-series with C&P20 head the Traystak feeder cannot be used. 2
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
35
For X component trolleys the Traystak feeder cannot be used. 2
2.3.3 Adapter
2
Avoid to drill through the table bed because of the modules, hoses and cables underneath. 2
2
With the S component trolleys for HF-series / X-series, the adapter and feeder cannot be fitted to
the table outside the machine, otherwise there is a risk of crashing during docking or the table
docking unit will not work. 2
The component tables must be screwed inside the machine (risk of tipping, risk of head crash).2
2.4 Scope of delivery
Traystak feeder
Adapter plate with drilling template
or
Adapter plate without drilling template
Documentation
2.5 Tools and consumables required
Drilling template
Drill with magnetic stand
Drill bit, diameter 4 mm, for predrilling
Drill bit, diameter 8.4 mm
Countersink for deburring
Tap wrench
Thread cutter M10
Cutting oil
Wiping cloth
Screw M10x 60 mm
Set of hexagon socket spanners
Set of fork wrenches
2