Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series 11/2006 Edition 47 2.9 Retrofit the SIPLACE HS-50 / HS-60 2.9.1 Work at the location : Dock the compone …

100%1 / 60
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
46
: Move the component trolley into the placement machine.
2
As you dock the component trolley, make sure that it does not collide with the tape guide channel
or nozzle changer (if fitted). 2
2
: Screw the component trolley tight in the machine and connect the component table clamp -->
Risk of head crash.
2
2
2.8.2 Working on the component trolley
: Remove the feeder fixing on the component trolley if present.
2.8.3 Software
: Switch on the machine and switch to the SITEST program.
: If necessary, deactivate the relevant nozzle changer under Gantries.
2
If you deactivate the nozzle changer, you will not be able to use the nozzle reject device. 2
2
2
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
47
2.9 Retrofit the SIPLACE HS-50 / HS-60
2.9.1 Work at the location
: Dock the component trolley out of the placement machine.
: Shut down the placement system and switch it off.
: Remove the nozzle changer carrier at this location by loosening the 4 screws on the H profile.
2
Screws
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
48
2
On newer HS-60 models, the feeder cover flaps are fitted with a Schmersal switch that must be
opened first. 2
2
: Disconnect the nozzle changer from the power and air supplies and close the air connections.
: Pull the cables and air connection out of the machine and into the side part.
: Screw on the cover plate in place of the nozzle changer (4 screws M6 x 15 mm).
2
In the retrofit kit are two cover plates included. One is for location 2, the other one for location 4.
Choose the right one. 2
2
Schmersal switch
4 screws
Cover plate