27 8 . TROUBLESHOOTING PR OBLEM POSSIBLE CAUSE CORRECTION Display does not light up • No power in puts • Check power cord connections • Turn on power System will not actuate • Supplied pressure dropped below “Low Pressur…

100%1 / 29
26
9. Wait until the system completes the rebooting sequence and the home
screen is displayed
10. Repeat sections 5.1.1 and 5.1.2 to re-calibrate the air pressure
27
8. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTION
Display does
not light up
No power inputs
Check power cord
connections
Turn on power
System will not
actuate
Supplied pressure
dropped below “Low
Pressure” setting
Foot switch not plugged
in or improperly
plugged in
Defective foot switch
Broken wire or loose
connection inside unit
Defective solenoid
Defective PC board
Increase supplied
pressure
Check foot switch
connection
Foot switch needs to be
repaired or replaced
Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
Replace solenoid
Replace PC board
System will not
pressurize
Insufficient air pressure
Air hoses not plugged
in
Regulator defective
Increase air supply
pressure
Check connection
Replace regulator
Inconsistent
dispense
Air bubbles in material
Dispense time is too
low
Needle clogged
De-air material
Increase dispense time
Replace needle
28
9. MAINTENANCE
The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, please follow below steps:
1. Make certain air supply is clean and dry.
2. Avoid connecting the unit to excessive moisture or solvent saturation
3. Avoid connecting air supply exceeding 100 psi (6.9 bars)
4. Use only Amyl Alcohol to clean outside surface of the main housing
5. Use only soft cloth to clean the display screen
10. LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of 2
years from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor
contact information, please visit www.techconsystems.com. OK International
reserves the right to make engineering product changes without notice.
All returns must be issued with a Returns Authorization number, prior to return.
Send warranty returns to:
Americas
OK International
10800 Valley View Street
Cypress, CA 90630
+1 714 230 2398
Europe
OK International
Eagle Close Chandler’s Ford Ind Est
Eastleigh, Hampshire
SO53 4NF
United Kingdom
+44 2380 489 100
Asia
Dover (Shenzhen) Industrial
Equipment Manufacturing Co., LTD.
4th Floor East, Electronic Building
Yanxiang Industrial Zone, High Tech Road
Guangmin New District
Shenzhen, P.R.C
+86 21 64952662
www.techconsystems.com