Service Manual SIPLACE SmartFeeder - 第154页
7 Repairs to SmartFeeder 8 mm X / Xi 7.15 Handle with control panel 154 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 7.15.3 Individual parts on the handle Spare parts req…

7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 153
7.15.2.2 Fitting the Control Panel and Board
► If this is not open, swing the bracket on the flat rib-
bon connection(2)
on the board upwards.
► Push the flat ribbon cable(1) through the foil stuff-
ing unit cap, as shown, with the blue side pointing
upwards.
► Push the flat ribbon cable(1), with the blue side
pointing upwards, further into the flat ribbon cable
connection(2)
, on the board.
Make sure that the flat ribbon cable contacts lie
against the contacts on the connection.
► Swing the bracket on the flat ribbon connection
down(2)
.
► Insert the control panel(3) with the marked pins
into the marked holes(4)
on the board.
► Push the control panel(3) together with the
board(4)
sideways into the feeder module guid-
ance provided.
Make sure that the flat ribbon cable is not pinched
or pulled out of the connection on the board.
► Carefully life the cap on the foil stuffing unit(5) into
the position shown on the feeder module base.
Make sure that the flat ribbon cable hangs out of
the cap as shown.
► Fasten the cap on the foil stuffing unit at the
marked points(6)
with 2 screws. Use a size 8
TORX screwdriver and 0.6 Nm for this.
► Make sure that the lock(7) on the feeder module
moves easily and that no components are trapped
or pinched.
► Fasten the left side cover (see 7.3.2 "Fitting the left
side cover" [}102]).

7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
154 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
7.15.3 Individual parts on the handle
Spare parts required
Fig.51: Individual parts on the handle SmartFeeder 8 mm X
NOTICE
Other slide for SmartFeeder 8mmXi
In order to visually differentiate Xi feeder modules from the "normal" X feeder modules, a
different slide is used, with a clearly corrugated surface on the outside.
Feeder module Position Item no. Designation
SmartFeeder 8mmX 1 03108403Sxx Slide for foil stuffing unit assy. X8Smart
SmartFeeder 8mmXi 1 03171389-xx Slide for foil stuffing unit assy. 4/8mm Xi
SmartFeeder 8mmX
SmartFeeder 8 mm Xi
2 03009150Sxx Pressure spring VD-090V
3 03095505-xx Retaining springs for foil stuffing unit X8S-
mart
4 03033796-xx RF-SN75-2.5 x 6-9.8
5 03101437Sxx Window for control panel X8Smart
6 03101508Sxx Cover for foil stuffing unit X8Smart
Tools required
●
Phillips screwdriver 0.9Nm
●
TORX screwdriver 0.6Nm, size T8
●
Tweezers or flat pliers

7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 155
7.15.3.1 Removing individual parts from the handle
► Carefully place the feeder module with the right side down on a stable, level and clean sur-
face.
► Remove the left side cover (see 7.3.1 "Removing the Left Side Cover" [}102]).
► Remove the operating panel (see 7.15.2.1 "Removing the Control Panel and Board" [}152]).
If you have removed the operating panel, the cover on the foil stuffing unit will be accessible and
can be replaced if necessary.
► Pull the slide up and out of the handle. (1)
► Remove the pressure spring. (2)
► Remove the screw which fastens the spring
hook(1)
to the handle.
► Remove the spring hook.