7 Repairs to SmartFeeder 8 mm X / Xi 7.6 Splice sensor 118 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 ► Push the filler pieceand the insertion tunnel in the direction …

7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 117
► Insert the splice sensor(4) in place of the
dummy, as shown.
Make sure that the 2 fixture pins point forwards
and the 3 contact pins point backwards.
► Push the splice sensor(4) forwards, in the direc-
tion of the arrow, as far as the stop.
► From above, insert the screw supplied "RF-
SN65-2.5 x 12-9.8" through the hole in the holder
on the insertion tunnel.(1)
► Fit the insertion tunnel onto the filler piece.(2)

7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
118 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
► Push the filler pieceand the insertion tunnel in
the direction of the arrow, towards the splice
sensor, as far as the stop.(1)
The splice sensor is automatically contacted by the
board on the filling piece and is then recognized by the
software.
► Fix the filler piece into place with the screw inser-
ted
and 0.6Nm.(2)
7.6.2 Replacing the splice sensor filling piece
7.6.2.1 Removing the splice sensor filling piece
► Remove the left side cover (see 7.3.1 "Removing
the Left Side Cover" [}102]).
► Place the feeder module in a stable, upright posi-
tion.
For feeder module without sensor insertion tunnel:
► Loosen and remove the TORX screw marked in
the diagram(1)
.
For feeder module with sensor insertion tunnel:
► Loosen the TORX screw.
► Lift the TORX screw and the sensor insertion tun-
nel(1)
up and out.

7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 119
► Push the filling piece(1) to the side.
► Remove the splice sensor(2).
► Swing the motor cable(1) down so that you can
see the connection for the sensor cable(2)
.
► Open the connection on the sensor cable(2).
► Pull the sensor cable(3) out of the connection.
► Pull the filler piece and sensor able up and out of
the "top stiffener".
Make sure that the sensor cable remains undam-
aged during this.