Service Manual SIPLACE SmartFeeder - 第118页

7 Repairs to SmartFeeder 8 mm X / Xi 7.6 Splice sensor 118 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 ► Push the filler pieceand the insertion tunnel in the direction …

100%1 / 246
7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 117
Insert the splice sensor(4) in place of the
dummy, as shown.
Make sure that the 2 fixture pins point forwards
and the 3 contact pins point backwards.
Push the splice sensor(4) forwards, in the direc-
tion of the arrow, as far as the stop.
From above, insert the screw supplied "RF-
SN65-2.5 x 12-9.8" through the hole in the holder
on the insertion tunnel.(1)
Fit the insertion tunnel onto the filler piece.(2)
7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
118 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
Push the filler pieceand the insertion tunnel in
the direction of the arrow, towards the splice
sensor, as far as the stop.(1)
The splice sensor is automatically contacted by the
board on the filling piece and is then recognized by the
software.
Fix the filler piece into place with the screw inser-
ted
and 0.6Nm.(2)
7.6.2 Replacing the splice sensor filling piece
7.6.2.1 Removing the splice sensor filling piece
Remove the left side cover (see 7.3.1 "Removing
the Left Side Cover" [}102]).
Place the feeder module in a stable, upright posi-
tion.
For feeder module without sensor insertion tunnel:
Loosen and remove the TORX screw marked in
the diagram(1)
.
For feeder module with sensor insertion tunnel:
Loosen the TORX screw.
Lift the TORX screw and the sensor insertion tun-
nel(1)
up and out.
7 Repairs to SmartFeeder 8 mm X / Xi
7.6 Splice sensor
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 119
Push the filling piece(1) to the side.
Remove the splice sensor(2).
Swing the motor cable(1) down so that you can
see the connection for the sensor cable(2)
.
Open the connection on the sensor cable(2).
Pull the sensor cable(3) out of the connection.
Pull the filler piece and sensor able up and out of
the "top stiffener".
Make sure that the sensor cable remains undam-
aged during this.