7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 151
7.15 Handle with control panel
7.15.1 Handle assembly
The handle assembly can not be replaced and is not available as a spare part.
7.15.2 Control Panel Assembly
Required spare part
Fig.49: Board assy. control panel (top), control panel assy. (bottom)
Fig.50: Cable control panel
Feeder module Item no. Designation
SmartFeeder 8mm X
SmartFeeder 8 mm Xi
03104269-xx Board assy. control panel X8Smart
03102428 -xx Control panel assy. X8Smart
03063592-xx Cable control panel X2x8
Tools required
Phillips screwdriver 0.9Nm
TORX screwdriver size T8, 0.6Nm
Tweezers or small screwdriver
7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
152 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
7.15.2.1 Removing the Control Panel and Board
Carefully place the feeder module with the right
side down on a stable, level and clean surface.
Remove the left side cover (see 7.3.1 "Removing
the Left Side Cover" [}102]).
Loosen the lock(1) in the position "unlocked".
Open the two marked TORX screws(2), with
which the cap on the foil stuffing unit is fixed.
Carefully lift the cap on the foil stuffing unit(3) a
little from the base of the feeder module. Make
sure that the flat ribbon cable is still fastened to
the control panel board.
Pull the control panel(4) out of the guidance, to-
gether with the board(5)
.
Open the bracket on the flat ribbon cable connec-
tion(6)
at the board.
Pull the flat ribbon cable(7) out of the flat ribbon
cable connection.
Pull the flat ribbon cable out of the foil stuffing
unit cap.
7 Repairs to SmartFeeder 8 mm X / Xi
7.15 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 153
7.15.2.2 Fitting the Control Panel and Board
If this is not open, swing the bracket on the flat rib-
bon connection(2)
on the board upwards.
Push the flat ribbon cable(1) through the foil stuff-
ing unit cap, as shown, with the blue side pointing
upwards.
Push the flat ribbon cable(1), with the blue side
pointing upwards, further into the flat ribbon cable
connection(2)
, on the board.
Make sure that the flat ribbon cable contacts lie
against the contacts on the connection.
Swing the bracket on the flat ribbon connection
down(2)
.
Insert the control panel(3) with the marked pins
into the marked holes(4)
on the board.
Push the control panel(3) together with the
board(4)
sideways into the feeder module guid-
ance provided.
Make sure that the flat ribbon cable is not pinched
or pulled out of the connection on the board.
Carefully life the cap on the foil stuffing unit(5) into
the position shown on the feeder module base.
Make sure that the flat ribbon cable hangs out of
the cap as shown.
Fasten the cap on the foil stuffing unit at the
marked points(6)
with 2 screws. Use a size 8
TORX screwdriver and 0.6 Nm for this.
Make sure that the lock(7) on the feeder module
moves easily and that no components are trapped
or pinched.
Fasten the left side cover (see 7.3.2 "Fitting the left
side cover" [}102]).