Service Manual SIPLACE SmartFeeder - 第163页
7 Repairs to SmartFeeder 8 mm X / Xi 7.17 Foil container Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 163 7.17.1.1 Removing the foil box ► Carefully place the feeder modu…

7 Repairs to SmartFeeder 8 mm X / Xi
7.17 Foil container
162 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
7.17 Foil container
7.17.1 Foil box
Spare part required
Fig.54: Foil box
Feeder module Item no. Designation
SmartFeeder 8mmX
SmartFeeder 8 mm Xi
03100963-xx Foil box with tape duct X8Smart
03100995-xx Foil box sheet for cover foil stuffing unit X8Smart
Tools required
●
Phillips screwdriver 0.9Nm
●
TORX screwdriver 0.6Nm, size T8
●
Flat-bladed screwdriver size 1
●
Tweezers

7 Repairs to SmartFeeder 8 mm X / Xi
7.17 Foil container
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 163
7.17.1.1 Removing the foil box
► Carefully place the feeder module with the left
side down on a stable, level and clean surface.
► Loosen the screws marked A with a TORX
screwdriver.
► Loosen the screw marked B with a Phillips
screwdriver.
► Slightly lift the right side cover at the back.
► Pull the foil box sheet towards the back and out
of the feeder module.
► Slightly lift the right side cover at the back.
► Pull the flap (1) vertically upwards and off the
shaft (2)
.
► Remove the shaft.

7 Repairs to SmartFeeder 8 mm X / Xi
7.17 Foil container
164 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
► Remove the rear sliding guide (see 7.2.1 "Re-
moving the Sliding Guide" [}100]).
► Carefully place the feeder module on its right
side.
► Remove the left side cover (see 7.3.1 "Removing
the Left Side Cover" [}102]).
► Loosen the screw marked B (M 2.5x5) with a
Phillips screwdriver.
► Loosen the 3 screws marked A (RF 2.5x6) with a
TORX screwdriver.
ð The lower stiffener (1) also loosened will be
pulled off the foil box at a later time.
► Remove the TORX screw (RF 2.5x7.5) fastening
the filler piece for the splice sensor.
► Remove the two TORX screws (RF 2.5x7.5)
fastening the foil box to the empty tape duct.
► Remove the two TORX screw fastening the foil
box (1)
to the foil stripping unit (2).