8 Repairs to SmartFeeder 2x8 mm X / Xi 8.7 Splice sensor / dummy Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 195 8.7.2 Fitting the splice sensor NOTICE Always fit both s…

100%1 / 246
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
194 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
Push the dummy sensor approx. 2 mm horizont-
ally to the right.
Carefully lift the dummy sensor.
Make sure that the two connection lines inserted
into the dummy sensor are not damaged.
Carefully swing the dummy sensor upwards.
Pull the cable about 4 cm out of the base unit of
the feeder module.
Push the connectors of the two cables out to
each side, out of the dummy sensor guidance.
Remove the dummy sensor.
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 195
8.7.2 Fitting the splice sensor
NOTICE
Always fit both splice sensors.
If you want to use splice sensors for the feeder module, both lanes need to be supplied with
splice sensors.
When you connect the splice sensors, make sure that you use the right cable for the lane in
each case:
- The cable for the splice sensor on the left lane has the colors red, white and black.
- The cable for the splice sensor on the right lane has the colors red, brown and black.
Pull the sensor cable for that lane out of the cable
duct.
Plug the connector for the sensor cable into the
connection on the splice sensor.
Carefully guide the sensor cable back into the
cable duct.
Place the splice sensor onto the lane.
Make sure that you do not pinch the cable but
that it is fed into the cable duct properly.
Push the splice sensorin the direction of the ar-
row, as far as the stop, towards the tape duct.
Make sure that the nib at the front of the splice
sensor is completely inserted into the tape duct.
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
196 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
Fix the splice sensor to the lane with the screws
provided.
Fit the second splice sensor in the other lane.
The procedure is the same as that for the first
splice sensor.
After installation, the splice sensors will be automatic-
ally recognized and do not require any additional activ-
ation.
8.7.3 Removing the splice sensor
Remove the screw fastening the splice sensor to
the lane.