Service Manual SIPLACE SmartFeeder - 第235页

8 Repairs to SmartFeeder 2x8 mm X / Xi 8.16 Handle with control panel Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 235 8.16.1 Removing the handle assembly ► Remove the le…

100%1 / 246
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
234 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.16 Handle with control panel
Spare part required
NOTICE
New spare part
Spare part "Handle X2x8" [03072432Sxx] is no longer available.
This item can only be replaced as a complete unit.
The new "Handle X2x8 assy. [03170776-xx] is available as a compatible replacement.
It is now possible to replace individual parts of this handle.
Fig.77: Handle X2x8 assy.
Feeder module Item no. Designation
SmartFeeder 2x8mmX 03170776-xx Handle X2x8 assy. (prefitted with flat ribbon cable)
SmartFeeder 2x8 mm Xi 03172629-xx Handle X2x8i assy. (prefitted with flat ribbon cable)
Tools required
Phillips screwdriver 0.6Nm
TORX screwdriver size T8, 0.6Nm
Tweezers
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 235
8.16.1 Removing the handle assembly
Remove the left and right side cover (see 8.3.1
"Removing the Left Side Cover" [}174] and 8.3.3
"Removing the Right Side Cover" [}175]).
Remove the cover on the foil container.
Carefully place the feeder module on its right side.
Remove the two pressure springs from the rock-
ers.
Open the bar on the flat ribbon connection on the
control board.(1)
Unplug the flat ribbon cable form the connection.
Carefully pull the flat ribbon cable completely out
through the feedthrough on the tape duct.(2)
Carefully pull the flat ribbon cable off the adhes-
ive points.
Remove the two screws marked in the diagram,
which are fastening the handle.
Stand the feeder module up.
Open the foil disposal flap.
Push the handle up to the right-hand side and out
of the feeder module base.
Close the foil container flap.
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
236 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.16.2 Fitting the handle assembly
Stand the feeder module up.
Open the foil disposal flap.
Push the handle from the right-hand side, as far
as the stop in the feeder module frame.
Close the foil container flap.
Place the feeder module carefully down on its
right side
Fasten the handle using the two marked (see dia-
gram) screws with 0.6Nm.
Fold the flat ribbon cable in exactly the same way
as the old cable.
Run the cable and press it into the cable duct and
onto the double-sided adhesive tape. Replace
the adhesive tape if required.
Carefully insert the flat ribbon cable completely
through the feedthrough on the tape duct.(1)
When running the cable, make sure that the blue
side points upwards at the end of the cable.
Insert the end of the flat ribbon cable (with the
blue side pointing upwards) as far as the stop in
the marked flat ribbon connection on the control
board.(2)
Close the connection and make sure that the
cable it firmly fitted.
Fit the two pressure springs into the rockers.
Fasten the cover on the foil container.
Fasten the left and the right side covers (see
8.3.2
"Fitting the Left Side Cover" [}175] and
8.3.4
"Fitting the Right Side Cover" [}176]).