Service Manual SIPLACE SmartFeeder.pdf - 第53页

6 Repairs to SmartFeeder 4 mm X / Xi 6.8 Foil rocker Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 53 6.8.1.1 Removing the Foil Rocker Assembly ► Carefully place the feede…

100%1 / 246
6 Repairs to SmartFeeder 4 mm X / Xi
6.8 Foil rocker
52 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.8 Foil rocker
6.8.1 Replacing the foil rocker assembly
Spare part required
Fig.10: Foil rocker assembly
NOTICE
New spare part
The new foil rocker has no metal deflector (A). The old foil rocker with metal deflector (B) is
no longer available.
Fig.11: Cable light barrier emitter
Feeder module Item no. Designation
SmartFeeder 4mm X
SmartFeeder 4 mm Xi
03136093-xx Foil rocker unit assy. X4Smart V2 (no longer avail-
able)
03226998-xx Foil rocker assembly X4Smart V3
03063591-xx Cable for light barrier emitter 2x8
Tools required
●
Flat-bladed screwdriver size 1 or tweezers
●
TORX screwdriver size T8
6 Repairs to SmartFeeder 4 mm X / Xi
6.8 Foil rocker
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 53
6.8.1.1 Removing the Foil Rocker Assembly
► Carefully place the feeder module with the right
side down on a stable, level and clean surface.
► Remove the two screws(1) which fasten the foil
rocker.
Use a size T8 TORX screwdriver for this.
► Pull the foil rocker up and off(2).
► Make sure that the flat ribbon cable(3) is not
stretched too much.
► Turn the foil rocker into the position shown in the
diagram.
► Swing the holder on the flat ribbon connection
up(4).
► Pull the flat ribbon cable(5) out of the flat ribbon
cable connection.
6 Repairs to SmartFeeder 4 mm X / Xi
6.8 Foil rocker
54 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.8.1.2 Fitting the Foil Rocker Assembly
► Turn the foil rocker into the position shown in the
diagram.
► If this is not open, swing the bracket on the flat
ribbon connection(2)
upwards.
► Push the flat ribbon cable(1), with the blue side
pointing upwards, into the flat ribbon cable con-
nection(2)
, as far as the stop.
► Make sure that the flat ribbon cable contacts lie
against the contacts on the connection.
► Swing the bracket on the flat ribbon connection
down(2)
.
► Carefully place the foil rocker unit(3) onto the
marked fixture holes.
Make sure that the cable(4) slides into the duct well
during insertion and is not bent. If there are any prob-
lems with this, open the left side cover of the feeder
module.
► Very carefully fasten the foil rocker unit with the
two marked TORX screws hand-tight. Use a size
8 TORX screwdriver for this.