Service Manual SIPLACE SmartFeeder - 第85页

6 Repairs to SmartFeeder 4 mm X / Xi 6.16 Control board Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 85 6.16.3 Performing a reference run Fig.25: Control panel 1. LED 8 …

100%1 / 246
6 Repairs to SmartFeeder 4 mm X / Xi
6.16 Control board
84 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
Connect the 3 flat ribbon cables(4-6) to the control
board. Proceed as follows for this:
Push the flat ribbon cable as far as the stop into
the connection shown in the diagram.
Make sure that the contacts are on the underside
of the cable and that the blue side of the cable
can be seen on the top.
Lock the connection (see the diagram, top right).
Insert the EDIF connector (7) into the marked
connection on the control board.
Align the position of the control board again, us-
ing the 3 holes in the control board and the 3
holes in the side cover.
Carefully place the feeder module with the left
side down on a stable, level and clean surface,
while holding the control board in its position.
Fasten the control board with the 3 Phillips screws
shown in the diagram(1)
to the right side cover.
Make sure that the EDIF connector is correctly in-
serted onto the control board.
Carefully fasten the EDIF connector with the TORX
screw shown in the diagram(2)
.
Use a size T8 TORX screwdriver with 0.2 Nm. for this.
Carefully place the feeder module with the right
side down on a stable, level and clean surface.
Fasten the left side cover (see section 6.3.2 "Fit-
ting the Left Side Cover" [}30]).
NOTICE
Reference run
After replacing the control board, it is essential that you perform a reference run of the
feeder module! For a detailed description, refer to section6.16.3
"Performing a reference
run" [}85].
6 Repairs to SmartFeeder 4 mm X / Xi
6.16 Control board
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 85
6.16.3 Performing a reference run
Fig.25: Control panel
1. LED 8 – 8mm pitch
(active only on SmartFeeder 8mmX)
6. FORWARDS button
2. LED 4 – 4mm pitch 7. BACKWARDS button
3. LED 2 – 2mm pitch 8. FOIL button
4. LED 1 – 1mm pitch 9. SET button
5. LED M – menu
Shines when an operator menu is active
Place the feeder module on a single slot EDIF or on a changeover table for X feeders which is
connected to a placement machine.
Press and hold the gray SET button(9) until the reference run is enabled.
Press the yellow foil button three times briefly(8).
After the first press of the FOIL button, the LEDM will switch on.
After the second press, LED1 will also be switched on.
After the third press, LED2 will also be switched on.
The menu for enabling the reference run has now been selected.
In addition to the SET button, also press the FORWARDS button(7).
LED8(1)
should now flash rapidly. If LED8 and LED4(2) flash, this indicates that there is a
feeder module error present (e.g. foil is tensioned or tape drive has an error) and the refer-
ence run can not be performed.
Release the FORWARDS button.
The reference run will start.
Release the SET button.
The reference run will be automatically finished. The control panel will then switch over to the
pitch display.
6 Repairs to SmartFeeder 4 mm X / Xi
6.17 Foil container
86 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.17 Foil container
6.17.1 Replacing the insertion foil container
Spare part required
Fig.26: Insertion foil container X4Smart V2
Feeder module Item no. Designation
SmartFeeder 4mmX
SmartFeeder 4mmXi
03126541Sxx Insertion foil container X4Smart V2
03033796-xx RF-SN75-2.5 x 6-9.8
03010209-xx ISO 7045 - M2.5 x 6-A2-50-H
Tools required
Phillips screwdriver 0.9Nm
TORX screwdriver 0.6Nm, size T8
Phillips screwdriver
6.17.1.1 Cleaning or replacing the foil container
NOTICE
Risk of confusion
The "insertion foil container X4Smart V2" has a label with details about the feeder module
(item number, serial number, barcode,…).
When replacing the insertion foil container, you need to create an identical new label and
attach it to the feeder module, so that the feeder module can be clearly identified again
after the replacement.
For a description of how to create new labels, see section 2.5 "Creating new labels for
feeder modules" [}15].
Carefully place the feeder module with the left side down on a stable, level and clean surface.
Remove the right side cover (see 6.3.3 "Removing the Right Side Cover" [}31]).