YSD_Users_E.pdf - 第364页

Chapter 1 Maintenance Contents 1. Maintaining machine per formance 1-1 1.1 Essential conditions and working environment 1-1 1.2 Importance of periodic inspections and cleaning 1-2 2. Preparing for maintenance tasks 1-3 2…

100%1 / 401
ii
Before using this machine
2. Maintenance list
n
Maintenance list
Maintenance tasks listed in the table below are classified as follows:
S: Inspection C: Cleaning L: Lubrication E: Replacement Task in parentheses: Perform if necessary
n
NOTE
For example, the task "Others – Air/mist filter – Filter" in the table below is classified as C (E). This means that the filter
should be cleaned once a year, and if the filter does not become clean, it should be replaced.
Section Unit name Check items Daily Weekly Monthly 6 Mon. 1 year 3 years
Head
assembly
parts
Nozzle Nozzle hole SC
Z-axis
Ball screw CL
Guide CL
Spline shaft Appearance CL
X and Y axes
X-axis
Ball screw SCL
Guide SCL
Y-axis
Ball screw SCL
Guide SCL
Conveyor
units
Board transport unit
Board sensor SC
Board clamped SC
Conveyor belt SC E
PU axis
Ball screw CL
Ball guide CL
W-axis
Ball screw CL
Guide CL
Hex spline CL
Others
Base Filter C (E)
Controller unit Filter C (E)
Air/mist filter Filter C (E)
UPS Battery E
Chapter 1 Maintenance
Contents
1. Maintaining machine performance 1-1
1.1 Essential conditions and working environment 1-1
1.2 Importance of periodic inspections and cleaning 1-2
2. Preparing for maintenance tasks 1-3
2.1 Tools and materials supplied with machine 1-3
2.2 Separately sold options 1-4
2.3 Required tools 1-5
1-1
1
Maintenance
1. Maintaining machine performance
The most important condition essential for maintaining the performance of the machine you purchased is
using it under good environmental conditions. Performing daily maintenance and periodic inspections is also
absolutely essential.
1.1 Essential conditions and working environment
n
Air
Item Description
Air pressure 0.45MPa or more
Air hose 8mm or more in inner diameter
Air Clean air passed through air dryer and air filter
n
Power
Item Description
Power supply 200/208/220/240/380/400/416VAC (±10%), 3-phase AC line
Frequency 50 Hz or 60 Hz
Power supply capacity 7.0KVA
Average power consumption 0.55kW
Maximum power consumption 1.9kW
Power supply connection Power cable conductor cross-section area: 3.3 mm
2
minimum
n
Environment
Item Description
Noise Conforms to EN 61000-6-2 standard
Humidity 20 to 80% (no condensation), optimal range: 50 to 60%
Temperature Functions guaranteed within 15 to 35°C. Machine precision guaranteed within 20 to 28°C.
Atmosphere No dust or powder. No significant noise generation.
Installation
Flat level location sturdy enough so no vibration occurs during operation.
Wooden floors in particular are unsuitable.
Altitude 1000m or less above sea level
Floor load-bearing strength Approx. 850kg/m
2
or more
n
NOTE
Keep the humidity at 40% or higher to prevent electrostatic charges. When using an industrial humidifier, use water