SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (S TA ) on the basis of station software version 505.03 SP 1 11/2005 Edition 29 These are the contents: 2 2 The data base interface can be co nfigured to a limite…
2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO
11/2005 Edition
28
[BMRID] [int] (4) NULL CONSTRAINT [DF_REEL_BMRID] DEFAULT (0), 2
[TRACE] [varchar] (255) NULL , 2
[KITID] [varchar] (30) NULL , 2
[LOT] [varchar] (30) NULL , 2
[DATECODE] [varchar] (30) NULL , 2
[SUPPLIER] [varchar] (30) NULL , 2
[EXPIRE] [datetime] (8) NULL , 2
[EVALUE] [real] (4) NULL , 2
[EUNIT] [varchar] (30) NULL , 2
[FLRLIFE_ID] [varchar] (15) NULL , 2
[FLRLIFE_REMAIN_PCT] [int] (4) NULL , 2
[POLARITY] [int] (4) NULL , 2
[rowguid] [uniqueidentifier] (16) ROWGUIDCOL NULL CONSTRAINT [DF_REEL_rowguid] DE-
FAULT (newid()) 2
2
After successful verification, a record is written to the table "TRACE_LOG". 2
TABLE [TRACE_LOG] 2
[PCBID] [varchar] (50) NOT NULL , 2
[RID] [varchar] (30) NOT NULL , 2
[MPROG] [varchar] (255) NOT NULL , 2
[QTY] [int] (4) NULL , 2
[FCODE] [varchar] (20) NULL , 2
[LOC] [varchar] (30) NULL , 2
[TRACE_STATION] [varchar] (50) NOT NULL , 2
[TIMESTAMP] [datetime] (8) Null 2
[KITID] [varchar] (30) NULL , 2
[PROGQTY] [int] (4) NULL 2
2
2
2

SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1
11/2005 Edition
29
These are the contents: 2
2
The database interface can be configured to a limited extent. For details, see the section on Con-
figuration. 2
2
2
2
2
PCBID “TIMESTAMP” by default
RID the scanned ReelId (without prefix)
MPROG
Panel name on Conv1# Panel name on Conv2,
only one panel name if both are the same
QTY Container size
LOC Table_no#Track_no#Division#Level#Tower
TRACE_STATION Line_name#Station_name
2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO
11/2005 Edition
30
2.6 Requirements
– Station software 505.03 SP1 must have been installed successfully and traceability 505.03
SP1 must be active.
– A SIPLACE machine of the type:
SIPLACE HS-50,
SIPLACE HS-50+
SIPLACE HS-60
and SIPLACE HF-Serie.
– Other requirements are described in the manual and the version description for Traceability
505.03 SP 1.
: Do not attempt to install the SOKO on a different software version.
The machine will not start up and you will have to deinstall the SOKO.
2.7 Configuration
2.7.1 Basics at the Programming system
On the programming system, the component verification flag must be set for every component
and the feeder pitch (required for the component level indicator threshold value "Remaining
length in mm") must be entered correctly. 2
Component verification and the Siemens wired hand scanner must be active on the machine. 2
2.7.2 Basics at the Station
Component verification must be active. 2
SIPLACE traceability should be inactive, but the item "Reread barcode if previous setup is identi-
cal" must be inactive. 2
The appropriate threshold values must have been set in the component level indicator. 2
2
2
2
2
2