CX-1_故障检修 - 第3页

故障检修 目录 i 目录 1 操作上的故障检修 1-1 贴片偏移 ································ 1-1 1-2 元件吸取错误 ······························ 1-6 1-3 激光识别(元件识别)错误 ························· 1-7 1-4 吸嘴装卸错误 ······························ 1-7 1-5 标记(BOC …

100%1 / 403
注意事项
(1) 未经许可,禁擅自复印,复制本书的部分或全部内容。(包括软件和程序)
(2) 本书的内容如有变更,恕不另行通告。
(3) 我们在编写本书内容时,力求准确无误。万一发现有错误,遗漏或可疑之处,请与所购买的
销售店或与本公司联系。
(4) 对于因错误操作所造成之结果,无论与第(3)项有关与否,本公司概不负责。敬请谅解。
(5) Microsoft Windows Microsoft Corporation 在美国和/或其他国家/地区的注册商标或商
标。本书中出现的其他公司名,产品名均为各公司的注册商标或商标。
故障检修 目录
i
目录
1 操作上的故障检修
1-1 贴片偏移 ································ 1-1
1-2 元件吸取错误 ······························ 1-6
1-3 激光识别(元件识别)错误 ························· 1-7
1-4 吸嘴装卸错误 ······························ 1-7
1-5 标记(BOC 标记、IC 标记)识别错误 ····················· 1-8
1-6 图像识别错误 ······························ 1-9
1-7 其它错误 ······························· 1-10
2 记录工具(Log Tool)
2-1 记录工具 ································ 2-1
2-2 自动获得记录的功能 ··························· 2-2
2-2-1
出错时的自动获得记录 ························ 2-2
2-2-2 生产停止前的自动记录取得 ······················ 2-3
3 錯誤消息集
3-1 错误信息一览······························· 3-1
3-2 图像错误的详细情况··························· 3-367
3-4 吸嘴装卸错误 ····························· 3-381
故障检修 操作故障的排除方法
1 操作故障的排除方法
本章以操作方法为中心,对CX-1使用中可能发生的问题及相应的措施进行说明。
以下将按照故障发生可能性的降序来进行说明,请按照编号顺序进行处理。
1-1 贴片偏移
1-1-1 整个基板发生贴片偏移(每个基板反复出现)
原因 措施
“贴片数据”的 X、Y 坐标输入错误。 重新设定“贴片数据”(确认 CAD 坐标或重新
示教等)。
BOC 标记位置偏移或脏污。
尤其是脏时,极其容易导致贴片偏移。
确认并重新设定 BOC 标记。
加强管理,以防弄脏 BOC 标记。
制作数据时,在未实施 BOC 校准的状态下,
贴片坐标进行示教。
制作好“基板数据”后,务必执行“BOC
准”然后再对“贴片数据”进行示教。 (参
见第 4-5-4-4-1 章 标记系:BOC)。
尽管 BOC 采用 CAD 坐标,但仍然可用基板数据
BOC 标记进行示教。
使用 CAD 坐标时,切勿进行 BOC 标记示教。
已对 BOC 标记进行示教时,就必须对所有贴
片坐标重新示教。
使用 CAD 数据时,CAD 数据的贴片坐标,或BOC
标记的坐标出现错误。
⑤确认 CAD 数据,出现错误时,要重新对全部
贴片数据进行示教。其中,整体偏向固定方
向时,移动基板数据的 BOC 坐标(例:在 X
方向偏移“0.1mm”时,所有 BOC 标记的 X
坐标都加上“0.1mm”)以校正偏移。
1-1