00192393-02 - 第39页

Retrofitting Instr uctions SIP LACE Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50 02/2003 Edition 2.1 Overview 37  5HWURILWWLQJ ,QVWU FWLRQV 0RGXODU +HDG 3&%RQ66+0)+0+6   2YHUYLHZ These in…

100%1 / 74
Modulare Koplatine an S-23, S-25 HM, F5 HM, HS-50 Nachrüstanleitung SIPLACE
1.7 Anhang Schaltpläne, Layout (Vision-Board) Ausgabe 02/2003
36
Retrofitting Instructions SIPLACE Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50
02/2003 Edition 2.1 Overview
37
5HWURILWWLQJ,QVWUFWLRQV0RGXODU+HDG
3&%RQ66+0)+0+6
 2YHUYLHZ
These instructions describe how to retrofit the "Modular head PCB assembly" on SIPLACE F5
HM, S-23, S-25 HM and HS-50 machines. Retrofitting on an F5 HM is not explicitly documented
with photographs, however this is done in much the same manner as for S-23/S-25 HM
machines. Procedural deviations are discussed at the appropriate point during implementation.
Only the Siemens SMD service engineer is permitted to perform the retrofitting.
The modular head PCBs have to be installed under the following conditions:
When retrofitting the optional PCB camera Multicolor.
(see the retrofitting instructions for the PCB camera Multicolor, Item no. 00192232-01, German
and English). For this reason, the retrofit kit "Modular head PCB" is also included in the PCB
camera retrofit kit for HS-50 and S-23/S-25 HM machines.
When there is fault in the existing "Conversion PCB, small axis"
The modular PCB boards must always be installed on all gantries.
The PCB unit of the "Head PCB, Assembly" (modular) consists of 4 PCBs:
Gantry head distributor HS-50 or S-23/S-25 HM or F5 HM (modular)
Processor board 80 C515C
SM board, modular
Vision board, modular
Item numbers: see Section 2.4.1. or Section 2.4.2 or Section 2.4.3.
There is a separate head PCB assembly for F5 HM machines (see Section 2.4.3). The required
ribbon cables are identical to those for the S-25 HM (S-23) however.
7DNHQRWHRI
To retrofit the modular head boards, relatively old S-23 machines that have been upgraded to
S-25 HM, you require 3 new 10-pin connectors and 1 new 16-pin connector that have to be
fitted on the existing ribbon cables (see Fig. 2.6.4), as described in this isntructions.
This is required to produce the strain relief for the cables.
The service center stocks the parts and special tools required for this purpose in a separate
service package (detail -> see Section 2.4.4).
Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50 Retrofitting Instructions SIPLACE
2.1 Overview 02/2003 Edition
38
Refer to the note regarding the head cover (see below).
NOTE
S-25 HM, F5 HM:
It is only necessary to use the "new" head cover (with bulge or - as a preliminary solution - a cutout
for the IC camera 16 x 16) if the FC camera 16 x 16 is on or is being installed on the 6-segment
revolver head). For this reason the new head cover is included in the retrofit kit of the
FC camera 16 x 16.
S-23, S-25 HM, F5 HM:
Without FC camera 16 x 16, the old head cover can be re-used if the cables of PCB camera Mul-
ticolor have been run as described here.
HS-50:
To date, no head cover is used on HS-50. Currently, no head cover was installed while retrofitting
the modular head PCB either because such was not yet available when the documentation was
prepared (beginning of April, 2001).
Before retrofitting the modular head PCB, check with the Service Center to ascertain the latest
status.