00192393-02 - 第55页
Retrofitting Instr uctions SIP LACE Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50 02/2003 Edition 2.6 Installing the Head PCB, Modular 53 .H\WR)LJ FR QWLQXHG 3. SM-Boa rd modul ar 4. Vision-Boar d modular…

Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50 Retrofitting Instructions SIPLACE
2.6 Installing the Head PCB, Modular 02/2003 Edition
52
,QVWDOOLQJWKH+HDG3&%0RGXODU
Å
Continue to wear the ESD bracelet (see CAUTION text above).
Å Pick up the pertinent new modular head PCB assembly:
(Item no.: see Section 2.4.1, Section 2.4.2 or Section 2.4.3).
.H\
1. Gantry head distributor, modular, basic board
2. Processor board 80 C515C
Retrofitting Instructions SIPLACE Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50
02/2003 Edition 2.6 Installing the Head PCB, Modular
53
.H\WR)LJFRQWLQXHG
3. SM-Board modular
4. Vision-Board modular
5. Spacer bolts with rubber buffer to fasten the head cover (open-end wrench, size 5.5 mm) *)
6. Spacer bolts to support the head cover (open-end wrench, size 5.5 mm) *)
*) and to fasten the head PCB assembly to the 4 spacer bolts on the head support
Å Comply with the ESD regulations. Use ESD tools and the ESD bracelet.
Å On each of the Placement head make the connections of the 4 ribbon cables on the bottom of
the "Gantry head distributor board" again.
Å Carefully place the new PCB assembly on the existing spacer bolts.
Å For the HS-50:
Re-use the 4 socket hex head cap screws M3 (size 2.5 mm) removed during disassembly to
fasten the PCB assembly to the 4 spacer bolts of the head support.
Å For the S-23, S-25 HM, F5 HM:
Use the 4 spacer bolts that were removed while working from the top of the PCB during the
disassembly of the "Conversion board, small axis".
With these 4 spacer bolts (open-end wrench size 5.5 mm) fasten the new PCB assembly on
the spacer bolts of the head support.
Refer to Fig. 2.6.3 to see how the spacer bolts are arranged:
- 2 spacer bolts that the head cover (Pos. no. 6) will rest on and
- 2 spacer bolts with rubber vibration dampers to fasten the head cover (Pos. no. 5).
Å The next step in the case of older S-23 or S-25 HM machines that have been upgraded from
older S-23 machines is to check whether the strain relief devices on the connectors of the new
PCBs still match the jack connectors on the existing ribbon cables.
To do so, proceed as described in Section 2.6.3.
Å The next step is to check the PIN allocation (see Section 2.6.4).

Modular Head PCB on S-23, S-25 HM, F5 HM, HS-50 Retrofitting Instructions SIPLACE
2.6 Installing the Head PCB, Modular 02/2003 Edition
54
8SJUDGHG2OGHU66+00DFKLQHV21/<,QVWDOOLQJ1HZ&RQQHFWRUV
Å
Check whether the strain relief devices for the new PCB assembly still fit, as shown below in
Fig. 2.6.4 and Fig. 2.6.5:
– on the 3 ribbon cables of the adjustment units (SLQconnectors) and
– on the 16-pin ribbon cable for vacuum (SLQconnectors)
.H\
1. Modular head PCB, complete, installed
2. Strain relief device on PCB connectors
3. NEW connector = large nose on the entire side = matching
4. OLD connector = small nose connector must be exchanged.
5. 2 ribbon cables, 40-pin, and 1 ribbon cable, 26-pin *)
*) These cables are always exchanged on HS-50 and on S-23, S-25 HM and F5 HM because the
cable run has been changed (see Fig. 2.6.7 to Fig. 2.6.11).