88192278-01-19 Installation Master - 第155页
PRINTER PREPARATION PRINTER ASSEMBLY Chapter Issue 15, May 20 Installation Manual 4.53 ProFlow unit into the connector (9PL61) located on the left hand side of the ProFlow , on the print carriage, figure in Step 7 refers…

PRINTER PREPARATION
PRINTER ASSEMBLY
4.52 Installation Manual Chapter Issue 15, May 20
Tighten using a 5mm Allen key.
4. Ensure that the locking clip on the pressure mechanism is pressed over to
the right and clicks into place, as shown in the figure below. This ensures
that the locking clip is in the correct position to secure the transfer head.
5. Locate and fit the ProFlow transfer head unit to the pressure mechanism by
means of the two locating dowels. Slide the unit onto the pressure
mechanism. Once the unit is slid fully home, it is secured by closing the
locking clip.
6. Connect both curly air lines to the self-seal pneumatic connectors situated
either side of the ProFlow printhead mechanism, figure in Step 7 refers.
7. Fit the electrical connection 9SK61 ProFlow Paste Level Sensor from the
Securing Bolts
Locking Clip

PRINTER PREPARATION
PRINTER ASSEMBLY
Chapter Issue 15, May 20 Installation Manual 4.53
ProFlow unit into the connector (9PL61) located on the left hand side of the
ProFlow, on the print carriage, figure in Step 7 refers.
NOTE
a. 1) An amplifier is connected to 9PL61 and the connection is made to
9PL62 on the amplifier.
b. 2) This electrical connection informs the printer of ProFlow fitment and
must always be connected whilst the ProFlow unit is fitted otherwise
damage may occur if printer is run.
Fitting ProFlow
ATx
To fit ProFlow ATx to the printer, carry out the following procedures:
• Fit ProFlow ATx System Mount
• Fit Transfer Head
• Level Transfer Head
• Fit Print Medium Cartridge
Mount Plate

PRINTER PREPARATION
PRINTER ASSEMBLY
4.54 Installation Manual Chapter Issue 15, May 20
Fit ProFlow ATx
System Mount
To fit the ProFlow ATx system mount to the printer, carry out the following
procedure:
1. Locate the four captive mount screws and two locator dowels on the rear of
the mount plate of the ProFlow ATx system mount assembly.
2. Lower the ProFlow ATx system mount beam by manually turning the Z-axis
motor pulley counter-clockwise. This action reveals the four captive screw
heads located on the front face of the mount plate.
NOTE
The captive screws may be hidden behind the components on the front of
the mount assembly. Move the beam down until they are fully revealed.
3. Locate the two locator dowel holes on the front face of the print carriage.
View on Rear of ProFlow Mount
Mount Plate
Captive Mount
Screw (4 Positions)
Locator Dowel
(2 Positions)
Z-Axis Motor
Pulley
Locator Dowel Holes
View on Front Left Corner