PRINTER PREPARATION PRINTER ASSEMBLY Chapter Issue 15, May 20 Installation Manual 4.63 T o fit a new print medium cartridge to the ProFlow A Tx system, carry out the following: 1. Open the printer cover . 2. Pull the lev…

PRINTER PREPARATION
PRINTER ASSEMBLY
4.62 Installation Manual Chapter Issue 15, May 20
Turning the levelling screws clockwise lowers the front of the transfer head.
Turning the levelling screws counter-clockwise raises the front of the trans-
fer head.
3. Tighten the two transfer head pin mount lock screws, using a 3mm Allen key.
4. Perform a print operation.
5. Inspect the print medium application; if further levelling is required, repeat
the procedure.
Fit Print Medium Cartridge
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
WARNING
MOVING PARTS. MOVING PARTS ARE PRESENT IN THE VICINITY OF THIS
WARNING LABEL, THESE PARTS HAVE THE POTENTIAL TO CAUSE INJURY.
NOTE
The following procedure assumes that an empty cartridge is fitted; if this is not
the case, open the lever arm (Step 4) and begin the procedure at Step 9 - “Fit
the new print medium cartridge to the filler tube assembly”.
View on Transfer Head Left Hand End (Through ProFlow Mount)
Transfer Head’s
Point of Rotation
Levelling Screws Clockwise
Levelling Screws Counter-clockwise

PRINTER PREPARATION
PRINTER ASSEMBLY
Chapter Issue 15, May 20 Installation Manual 4.63
To fit a new print medium cartridge to the ProFlow ATx system, carry out the
following:
1. Open the printer cover.
2. Pull the lever arm towards the left side of the printer.
View on Front
Print Medium
Level Sensor
Print Medium
Cartridge Holder
Print Medium
Filler Tube
Assembly
Print Medium Pneumatic
Delivery Mechanism
View on Left Front of ProFlow ATx System

PRINTER PREPARATION
PRINTER ASSEMBLY
4.64 Installation Manual Chapter Issue 15, May 20
3. Rotate the print medium cartridge anti-clockwise 90°.
NOTE
During removal of the print medium cartridge, the filler tube assembly
remains attached to the nozzle of the cartridge. Do not remove the print
medium cartridge from the cartridge holder assembly until the cartridge has
been fully rotated 90° so that the filler tube adaptor is free to be removed.
4. Remove the empty print medium cartridge and filler tube assembly.
NOTE
The filler tube assembly consists of the filler tube, the elbow fitting, and the
filler tube adaptor and ‘o’ rings; these are removed as a single assembly.
5. Unscrew the print medium cartridge from the filler tube assembly.
6. Dispose of the used print medium cartridge in accordance with any National,
Federal, or local waste disposal or recycling regulations.
7. Fit the new print medium cartridge to the filler tube assembly.
8. Fit the filler tube assembly to the transfer head.
9. Rotate the print medium cartridge clockwise 90° towards the ProFlow ATx
mount to lock the filler tube assembly into place.
10. Close the print medium cartridge holder lever.
11. Close the printer cover.
View on Left Front of ProFlow ATx System