PRINTER PREPARATION PRINTER ASSEMBLY 4.64 Installation Manual Chapter Issue 15, May 20 3. Rotate the print medium cart ridge anti-clockwise 90°. NOTE During removal of the print medium cartridge, the filler tube assembly…

PRINTER PREPARATION
PRINTER ASSEMBLY
Chapter Issue 15, May 20 Installation Manual 4.63
To fit a new print medium cartridge to the ProFlow ATx system, carry out the
following:
1. Open the printer cover.
2. Pull the lever arm towards the left side of the printer.
View on Front
Print Medium
Level Sensor
Print Medium
Cartridge Holder
Print Medium
Filler Tube
Assembly
Print Medium Pneumatic
Delivery Mechanism
View on Left Front of ProFlow ATx System

PRINTER PREPARATION
PRINTER ASSEMBLY
4.64 Installation Manual Chapter Issue 15, May 20
3. Rotate the print medium cartridge anti-clockwise 90°.
NOTE
During removal of the print medium cartridge, the filler tube assembly
remains attached to the nozzle of the cartridge. Do not remove the print
medium cartridge from the cartridge holder assembly until the cartridge has
been fully rotated 90° so that the filler tube adaptor is free to be removed.
4. Remove the empty print medium cartridge and filler tube assembly.
NOTE
The filler tube assembly consists of the filler tube, the elbow fitting, and the
filler tube adaptor and ‘o’ rings; these are removed as a single assembly.
5. Unscrew the print medium cartridge from the filler tube assembly.
6. Dispose of the used print medium cartridge in accordance with any National,
Federal, or local waste disposal or recycling regulations.
7. Fit the new print medium cartridge to the filler tube assembly.
8. Fit the filler tube assembly to the transfer head.
9. Rotate the print medium cartridge clockwise 90° towards the ProFlow ATx
mount to lock the filler tube assembly into place.
10. Close the print medium cartridge holder lever.
11. Close the printer cover.
View on Left Front of ProFlow ATx System

PRINTER PREPARATION
PRINTER ASSEMBLY
Chapter Issue 15, May 20 Installation Manual 4.65
External Solvent Tank
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
NOTE
Changing solvent types may cause unexpected chemical reactions and
degradation within the solvent feed tube. ASM recommend that if the solvent is
changed to a different type, the solvent feed tube, from the solvent tank to the
cleaner pump, is replaced.
For printer types 1 - 4 the external solvent tank may be fitted to the rear or the
side of the printer. The support plate on the external solvent tank is configured
differently from side or rear fitting due to baffle plates covering the cooling fans
at the rear of the printer.
The external solvent tank used on type 5 printers is free standing.
To fit the external solvent tank to printer types 1 - 4, carry out the following:
1. Configure the support plate of the external solvent tank for rear or side fitting
to the printer.
Rear Fitting Side Fitting
Support Plate Support Plate