Installation Manual, Station Software Version 604.01 SP1 Issue 12/2007 3.2 Upgrade from V ersion 601.x or 602.x Caution: For upgrading to the software version 604.x, pl ease consider the installation manual “Windows Embe…

Installation Manual, Station Software Version 604.01 SP1 Issue 12/2007
3 Upgrade to the 604.xx software version
This chapter describes which steps you have to attend when upgrading from different software versions.
When upgrading the station software, always check the eSW versions and download the current versions if
necessary.
3.1 Upgrade from Version 603.x
Caution:
For upgrading to the software version 604.x on the SIMATIC BoxPC 627, please consider the
installation manual “Windows Embedded XP operating system for the MC German and
English” (00195327-xx). Therfor, the standard media package (03054699-xx) is required.
It is not necessary to install the Windows embedded XP operating system for the other
machines.
- Fix the temperature warning labels (03031926-01) at the C&P20 head (see the figure).
- After an upgrade to the 604.xx software version, calibrate the heads of the D1, D2 and D4 machines.
The temperature compensation is activated for these machines.
- If the machine can not be started after the upgrade to the software version 604.xx, please consider the
technical information TI 2006-01C08 or contact your Siemens service technician.
8 of 47

Installation Manual, Station Software Version 604.01 SP1 Issue 12/2007
3.2 Upgrade from Version 601.x or 602.x
Caution:
For upgrading to the software version 604.x, please consider the installation manual “Windows
Embedded XP operating system for the MC German and English” (00195327-xx).
Therfor, the standard media package (03054699-xx) is required.
- For SIPLACE X4, X2 and X3 machines with CPU 076 the following upgrade packages for the machine
controller are required:
- Upgrade package for SIPLACE X4 with CPU 076 for computer upgrade to CPU 086
Item number: 03029123S03
- Upgrade package for SIPLACE X2 and X3 with CPU 076 for 128 MB memory expansion
Item number: 03051831
- Fix the temperature warning labels (03031926-01) at the C&P20 head (see the figure).
- After an upgrade to the 604.xx software version, calibrate the heads of the D1, D2 and D4 machines.
The temperature compensation is activated for these machines.
- If the machine can not be started after the upgrade to the software version 604.xx, please consider the
technical information TI 2006-01C08 or contact your Siemens service technician.
9 of 47

Installation Manual, Station Software Version 604.01 SP1 Issue 12/2007
4 Requirements
4.1 SIPLACE X series and D series software components
4.1.1 Station
The station uses the following operating system configuration:
• Station computer: Microsoft Windows XP Professional
(including Service Pack 2 and most recent hotfixes)
• Machine controller: Microsoft Windows embedded XP (SP2)
4.1.2 Machine components
The following versions of other machine components are required for the station software to function
correctly:
Station computer SIPLACE Vision Machine controller SIPLACE Pro
Version 604.01 SP1 Version 341 SP1 Version 604.01 Version 5.0
Caution:
The functional statuses of the station computer, vision and machine controller software must
be compatible.
10 of 47