YS24X_Mainte_E - 第154页

6-18 6 How to replace consumable parts r Check the belt rotating condition. 1. Make sure that the board clamp top sur face is approx. 0.5mm lower than the belt upper sur face. 2. Close the machine’s safety cover , and ca…

100%1 / 162
6-17
6
How to replace consumable parts
q
Clean the guides and pulleys.
1. Use a vacuum assembly (option) to
suction the belt wear debris on the belt
guides and sensors, etc.
2. Use a plastic spatula or similar tool to
remove the belt wear debris adhering to
the outer peripheral surface of the
pulleys.
3. Use a brush or similar tool to remove the
belt wear debris caught in the belt
guides.
53630-L4-00
c
CAUTION
Use a plastic spatula and brush to avoid scratching the
pulleys and guides.
c
CAUTION
Do not use a solvent (IPA, etc.) unless the guides and
pulleys are excessively dirty. If using a solvent, be
careful not to spill the solvent on the bearing in the
pulleys during cleaning.
w
Attach the conveyor belt.
1. Temporarily attach the new conveyor
belt by hooking to the pulley.
2. Insert the shaft through the driving pulley.
3. Tighten to secure the spline shaft with the
fixing bolt.
4. Move the pulley that tension is applied
to the position marked in Step 4, and
tighten the fixing bolt.
5. When the belt is loose, adjust the position
of the pulley to apply belt tension.
n
NOTE
For the tension measurement position and tension
standard of the machine’s conveyor belt, see the figure
in Step 9 of "
n
Dual stage specification : Replacing the
conveyor belt other than that of W2-axis".
c
CAUTION
The tightening standard of the securing bolt of pulley
that tension is applied is 5.5N·m. Be cautious not to
tighten too hard.
e
Attach the board clamp plate.
1. Fit the board clamp plate into its original
position and tighten the board clamp
plate mounting bolts with a hex wrench
(3).
2. Remove the square cloth on the push-up
plate.
53632-L4-00
Cleaning the guide and pulleys
Step 11
Brush
Belt guides
Belt wear debris
sticking to pulley
Spatula
(made of plastic)
Outer peripheral surface
of pulley
Step 13,14
Mounting the board clamp plate
Board clamp plateBoard clamp plate mounting bolt
0.5 mm
Board clamp
Belt upper surface
6-18
6
How to replace consumable parts
r
Check the belt rotating condition.
1. Make sure that the board clamp top
surface is approx. 0.5mm lower than the
belt upper surface.
2. Close the machine’s safety cover, and
cancel the emergency stop. If the
machine could be equipped with a
carriage, set the carriage.
3. On the [Unit] - [Conveyor] screen, press
the [Conveyor In] button or [Conveyor
Out] button to turn on the conveyor
motor and check the belt rotation.
4. If the rotation speed fluctuates or there is
slack in the belt, adjust the position of
the pulley that tension is applied, and
adjust the pulley’s position again.
54603-L4-00
c
CAUTION
When the difference between the belt upper surface
and board clamp top surface is very little, the board
transfer error may occur easily. In this case, contact
YAMAHA sales representative.
Conveyor operation check
Step 14
Conveyor drive buttons
Left Right
Low Left Low Right
Appendix
Appendix
Contents
1. Specifications A-1
1.1 Air regulator unit A-1
1.2 Power connection terminals A-2
1.3 Connection between machines A-3
1.3.1 PREVIOUS INTERFACE connector A-3
1.3.2 NEXT INTERFACE connector A-4
2. Warranty A-5