YS24X_Mainte_E - 第156页

A-1 Appendix 1. Specifications 1.1 Air regulator unit T he air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the front lower left panel. A digital pressure gauge is pr…

100%1 / 162
Appendix
Appendix
Contents
1. Specifications A-1
1.1 Air regulator unit A-1
1.2 Power connection terminals A-2
1.3 Connection between machines A-3
1.3.1 PREVIOUS INTERFACE connector A-3
1.3.2 NEXT INTERFACE connector A-4
2. Warranty A-5
A-1
Appendix
1. Specifications
1.1 Air regulator unit
The air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the
front lower left panel. A digital pressure gauge is provided on the front left of the machine.
Air pressure regulator and pressure gauge
Digital pressure gauge (A-table)
Digital pressure gauge (B-table)
Source air
connector
Air pressure
regulator
(B-table)
Air pressure
regulator
(A-table)
Air supply/exhaust
switch (valve)
53A01-L4-10
n
Supply air pressure
This is the pressure of the source air supplied to the machine. Before setting the air pressure with the air regulator, make
sure that this supply air pressure is in the following optimal range.
YS24X : 0.45MPa to 0.70MPa
n
Digital pressure gauge
Shows the supply air pressure (upper reading) and pressure-drop detection level (lower reading). A normal pressure value
is shown in green, and a pressure value lower than the pressure-drop detection level is shown in red.
n
Air pressure setting and pressure-drop detection level
Air pressure setting for machine (upper reading) : 0.40MPa to 0.41MPa
Pressure-drop detection level (lower reading) : 0.33MPa
n
Air supply/exhaust switch (valve)
Turning this switch to the right shuts off air supply and exhausts air that remains inside the machine.
n
Source air connector
Prepare an air hose with an inner diameter of at least 8mm having a 40SH socket (Nitto Koki, or equivalent), and connect
it to this connector. Use dry, clean air passed through an air filter.
A-2
Appendix
1.2 Power connection terminals
The power connection terminals are located inside the lower right panel on the front of the machine. Connect
the power cable leads as shown below to the L1, L2, L3 and ground terminal (PE) on the power terminal block.
n
Power supply specifications
Model name Power Frequency Power capacity
YS24X 3-phase AC 200/208/220/240/380/400/416V (±10%) 50/60Hz 7.7kVA
Power input terminals
(L1, L2, L3) and ground terminal
Main breaker
Power cable
Power connection terminals
53A02-L4-00
Fork-tongue crimp terminal
Power cable example
L1
L2
L3
PE
L=100mm
Ring-tongue crimp terminal
53A05-L4-00
c
CAUTION
Use a power cable whose conductor cross-section area is greater than 5.5mm
2
.
w
WARNING
TO AVOID THE RISK OF ELECTRICAL SHOCK, MAKE SURE THAT THE POWER SOURCE IS OFF BEFORE CONNECTING THE
POWER CABLE. ALSO MAKE SURE THAT THE GROUND CABLE IS SECURELY CONNECTED TO THE MACHINE.