00196674-01 - VD SetupCenter V3.3_de_en - 第28页
Restrictions Known Facts / Problems (General) Change in B ehaviour - Locking Instead of Tear ing Down 28 Version Description SIPLACE Setup Center 3.3
Restrictions
Barcode Fragment Known Facts / Problems (General)
Version Description SIPLACE Setup Center 3.3
27
6.2.14 Barcode Fragment
The maximum length of a barcode fragment is 255 characters, except the barcode fragment ‘Unique
ID’ with 40 signs. The length is also restricted by the barcode reader type used, by the barcode code
(e.g. Code 3of9, EAN 128 etc.) and by the barcode contents. It is therefore impossible to give a fixed
length restriction.
The first configured barcode of a barcode label must have a minimum length of 5 letters. It doesn't
matter whether it is divided on one fragment or several fragments.
6.2.15 Change in Behaviour - Locking Instead of Tearing Down
In exceptional circumstances, it may happen that tracks on a station are locked by Setup Center but
that this locking state no longer persists in Setup Center so that the tracks cannot be unlocked
automatically.
In this case the locks can be synchronized with the station: Right-clicking on the relevant station
opens a menu in which the locks will be synchronized by left-clicking on the menu item
'Synchronizing locks'.
Restrictions
Known Facts / Problems (General) Change in Behaviour - Locking Instead of Tearing Down
28 Version Description SIPLACE Setup Center 3.3

Annex
Standards
Version Description SIPLACE Setup Center 3.3
29
7Annex
7.1 Standards
SIPLACE recommends the observance of the following standards for all line computers (SIPLACE Pro
Server, SIPLACE Pro Client, SIPLACE stand-alone computer configuration).
Obervance of standards
Product safety
Global IEC 60950
Europe EN 60950
USA UL 60950 3rd. Ed.
Canada CAN/CSA-C22.2 No. 60950 3rd ed.
Electromagnetic compatibility
Europe EN 55 022 Class B, EN 55024,
EN61000-3-2 /-3
USA / Canada FCC class A
Declaration of conformity
Europe (CE) 89/336/EWG (EMW)
72/213 EEC (LVD)
North America FCC class A
Applicability
Europe EN ISO 9241-11