Micron Technical Reference V9 Volume 1 - 第119页

POWER SUPPLY M37 OVERVIEW Chapter Issue 13, Jan 17 Technical Reference Manual 5.5 Figure 5-5 T ype 5 Covers Item Description Item Desc ription 1 Printh ead Cover Interlock 4 Mains Iso lator Switch 2 System Button 5 E Sto…

100%1 / 290
POWER SUPPLY M37
OVERVIEW
5.4 Technical Reference Manual Chapter Issue 13, Jan 17
Figure 5-4 Type 4 Covers
Item Description Item Description
1 Front Printhead Cover Interlock 4 M37 Power Supply Enclosure
2 System Button 5 Mains Isolator Switch
3 Two Button Control 6 E Stop Button
POWER SUPPLY M37
OVERVIEW
Chapter Issue 13, Jan 17 Technical Reference Manual 5.5
Figure 5-5 Type 5 Covers
Item Description Item Description
1 Printhead Cover Interlock 4 Mains Isolator Switch
2 System Button 5 E Stop Button
3 Two Button Control 6 M37 Power Supply Enclosure
2
4
3
1
5
6
3
POWER SUPPLY M37
OVERVIEW
5.6 Technical Reference Manual Chapter Issue 13, Jan 17
WARNING
LETHAL VOLTAGE. DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT.
ENSURE ALL ELECTRONIC COVERS AND MAIN MACHINE COVERS ARE FITTED
BEFORE OPERATING THIS EQUIPMENT.
Mains input power (100V to 240V) to the machine is routed to the mains isolator
switch at the front of the machine. From the mains isolator it is fed to the M37
power supply crate, through the cable gland at the rear panel, to the three
terminal blocks TB1 (live), TB2 (neutral) and TB3 (earth). From the terminal
blocks mains power is supplied to the following:
M37SK31 PC Supply
M37SK32 Monitor Supply
M37SK33 Spare
M37SK34 Spare
M37SK35 Internal Vac Pump via Mains Filter and CB34
PSU
The PSU is a Switched Mode Power Supply Unit (SMPSU) which converts the
ac into the following dc supplies:
•+24V US
+24V SW
•+5.5V
•+12V
•-12V
•+42V
+48V (See note)
NOTE
The PSU upper voltage is set to +42V except for Type 1 machines that are set
to +48V.
The dc supplies from the PSU are fed to the power distribution PCB. Mounted
on the power distribution PCB is the PSU monitor board which enables moni-
toring of the power supplies.
An E Stop loop, front cover interlock, rear cover interlock/interlock blanking plug
and E Stop relay are fitted to ensure motor power is removed if the front
printhead cover or rear cover is opened or the machine is crash stopped by
pressing an E Stop button.
A two handed safety relay, left jog button and right jog button are fitted to enable
certain functions to be performed with the front printhead cover open.
The M37 power supply crate has mains power available; when access to the
components of the enclosure is required, observe the following warning: