Micron Technical Reference V9 Volume 1 - 第276页

PROFLOW MODULE OVERVIEW 11.2 Technical Reference Manual Chapter Issue 2, Aug 14 The ProFlow mechanism is driven backwards and forwards across the stencil by the print carriage a pplying printable material directly onto t…

100%1 / 290
PROFLOW MODULE
OVERVIEW
Chapter Issue 2, Aug 14 Technical Reference Manual 11.1
CHAPTER 11 PROFLOW MODULE
OVERVIEW
Item Description Item Description
1 ProFlow Printhead Mechanism 3 ProFlow Transfer Head
2 ProFlow Pressure Mechanism 4 Print Carriage
1
2
3
4
PROFLOW MODULE
OVERVIEW
11.2 Technical Reference Manual Chapter Issue 2, Aug 14
The ProFlow mechanism is driven backwards and forwards across the stencil
by the print carriage applying printable material directly onto the stencil. This
alleviates the need for squeegees and a paste dispenser.
The ProFlow mechanism is raised and lowered, to the stencil by means of a
stepper motor, applying a downward force directly onto the stencil providing a
positive seal between the transfer head and stencil. This eliminates leakage of
print material above the stencil.
Paste pressure (pneumatic), is applied to the piston crosshead exerting a force
onto the print material which, in turn, forces print material into the ProFlow
conditioning chamber and into the stencil apertures.
As the unit moves across the stencil the trailing wiper, within the transfer head,
lifts the print material from the stencil surface, clearing the stencil of print
material and creating a rolling movement of material within the conditioning
chamber.
Figure 11-1 ProFlow Cross Section (with cassette option)
ProFlow Pressure
Mechanism
Transfer
Head
Stencil
Board
ProFlow Movement (Y Axis)
Wiper
Piston
Crosshead
Pneumatic
Pressure
System Pressure
Print Material
Side Chambers
Cassette
Nozzle
Cassette
Plunger
PROFLOW MODULE
OVERVIEW
Chapter Issue 2, Aug 14 Technical Reference Manual 11.3
The sensor used to detect paste is:
ProFlow Paste Level Sensor - Giant Magneto resistive (displays to the
operator a percentage of paste remaining (time-to-go))
The sensor is fitted to the left hand side pressure mechanism pneumatic
actuator, as shown in the figure below.
Figure 11-2 ProFlow Sensor and Stepper Motor Locations
View on Rear of ProFlow Printhead Mechanism
ProFlow Home Sensor
Drive Belt
Stepper Motor
View on Front of ProFlow Pressure Mechanism (cover removed)
Pneumatic Actuator
15
0
30
Paste Level Sensor