Micron Technical Reference V9 Volume 1 - 第279页

PROFLOW MODULE ELECTRICAL SCHEMATIC Chapter Issue 2, Aug 14 Technical Reference Manual 11.5 ELECTRICAL SCHEMA TIC ProFlow Fitted Link Motor 2 B- Motor 2 B + Motor 2 A- Motor 2 A + Print Carriage Drag Chain 9PL08 9PL17 Pr…

100%1 / 290
PROFLOW MODULE
OVERVIEW
11.4 Technical Reference Manual Chapter Issue 2, Aug 14
The following configurations of ProFlow are available for use on the machine:
Cassette The ProFlow cassette is available in 300mm size only (capacity approximately
800g - 850g solder paste).
Transfer Head The table below lists the types of optional transfer head units and sizes
available, for use with ProFlow:
NOTE
All of the above cassette transfer heads are fitted with the standard 300mm
cassette and 300mm piston crosshead. A dedicated piston crosshead is
required for each rechargeable transfer head size.
Transfer Head Type
Transfer Head Sizes (mm)
150 300 350 400 450 500
Cassette Type (single conditioning chamber) Yes Yes Yes
Cassette Type (dual conditioning chamber) Yes Yes Yes
Rechargeable Type (single conditioning chamber) Yes Yes Yes Yes Yes
Rechargeable Type (dual conditioning chamber) Yes Yes Yes Yes Yes Yes
PROFLOW MODULE
ELECTRICAL SCHEMATIC
Chapter Issue 2, Aug 14 Technical Reference Manual 11.5
ELECTRICAL SCHEMATIC
ProFlow
Fitted Link
Motor 2 B-
Motor 2 B+
Motor 2 A-
Motor 2 A+
Print Carriage
Drag Chain
9PL08
9PL17
Print Carriage I/O
Node 3
N3PL13
N3PL17
N3SK2
N3SK1
N3SK3
N3PL8
9SK25
NextMove ES
(I/O Node 1)
NextMove
Interface
Dual Stepper
Card X2
M36 Machine Control
PC
Motherboard
Step 4
M36PL12
M36PL21
CAN
In
CAN
Out
Node Power
Stepper
Motor
(9M4)
ProFlow
Home
(9SE05)
+12V
0V
Signal
Pneumatic
Valve
(9S0L25)
+
-
+24V
Monitor O/P
I/P Signal
0V
ProFlow Pressure
Regulator
M18SK02
+12V
0V
Signal
Paste
Level
(9SE25)
ProFlow Paste
Level Amplifier
19
9SK61
9SK61
ProFlow
Fitted
Link
Cassette Low
9PL62
ProFlow ‘Time To Go
Option’
USB 4
3PL35
M36PL28
PROFLOW MODULE
ADJUSTMENTS AND SETTINGS
11.6 Technical Reference Manual Chapter Issue 2, Aug 14
ADJUSTMENTS AND SETTINGS
ProFlow Paste
Level Sensor
There is no adjustment and setting for this sensor.
ProFlow Stencil
Support
The ProFlow stencil support option provides stencil support when printing
boards that are narrower than the ProFlow transfer head, thus avoiding poten-
tial paste smearing onto the top of the stencil and stabilising the pressure within
the transfer head.
The standard height when the adjustable tooling top is in the closed position is
81mm. The support comprises the following items:
Changeable Gauge Plate
Tooling Bottom
Adjustable Tooling Top
NOTE