JaNets Instr ucti on Man ual 1. Overview 1-7 Some functio ns work diff erently d ependi ng on whet her t he setting of connect ion t o Data Mana ger is enabled or dis abled. I f the descri ption is ef fe ctive on ly when…

100%1 / 755
JaNets Instruction Manual
1. Overview
1-6
If the Line Manager option is added, the EPU and line can be selected for the line configuration in
the shop floor setup.
The operations of some functions may be changed depending on this line configuration setting. In
the explanation of the above, EPU modeis described when EPU is selected, and line mode is
described when the line is selected.
Only when the Line Manager option is added, it is described or is indicated for the
chapter No. in the explanation that is effective in the selected line mode.
1.2.3 External output function
This function is an option of Line Manager.
If the external output function is added, the machine information obtained from JaNets can be
output externally.
For details, refer to Instruction Manual for the external output function.
1.2.4 Data Manager
Data Manager is an option of Basic Editor. The descriptions and titles of functions you can use when
this Data Manager option is enabled are marked in this Manual.
Only in case of Basic Editor, its functions that can be used when a Data Manager option is installed
are different from those when two options, Line Manager are Data Mange are installed.
Basic Editor + Data Manager
Machine data and Component data can be shared with JaNets systems connected to Data
Manager.
Name
Overview
Shopfloor Setup
Sharing of definition data of the Shopfloor equipment
configuration (such as a machine, a feeder and a nozzle) and
environmental setup information such as a unit system
Component Database
Sharing of Component data
Basic Editor + LineManager + Data Manager
Floor, line and machine data, component, mark, feeder-setup data, production program and
reservation file data can be shared between JaNets systems connected to Data Manager.
Name
Overview
Shopfloor Setup
Sharing of definition data of the Shopfloor equipment
configuration (such as a floor, a line, a machine, a feeder and a
nozzle) and environmental setup information such as a unit
system
Program Explorer
Sharing of production programs and reservation files
Control of a master file of production programs
Component Database
Sharing of Component data
Mark Database
Sharing of BOC mark and area fiducial mark data
Feeder Set Database
Sharing of feeder set data
Line
Data Manager
JaNets Instruction Manual
1. Overview
1-7
Some functions work differently depending on whether the setting of connection to Data Manager is
enabled or disabled. If the description is effective only when the system is connected to a server, it
is described so or is shown together with the corresponding section number.
1.2.5 Equipment Manager
Equipment Manager is an option of Line Manager. The functions, which can be used when the
Equipment Manager option is enabled, are provided with a mark in the description or title in this
document.
When you use Equipment Manager, you can use the following functions: production line
configuration including a printer and an inspection machine, online PWB production and linkage
between machines.
Name
Overview
Shopfloor Setup
Line configuration including a printer and an inspection
machine
Setting of the device linkage function.
Program Editor
Association of production programs to be used with a printer
and an inspection machine
Setting of the device linkage function.
Program Downloader
Online production with a production line including a printer and
an inspection machine
Setting of the device linkage function.
1.2.6 TraceMonitor
TraceMonitor is an option of Line Manager. Functions you can use when the TraceMonitor option
is enabled are described in this manual or the corresponding mark is put to the respective titles for
the functions so that you can know it immediately.
When you use TraceMonitor, it collects information on each device to accumulate the information.
When you want to just refer to information collected with JaNets with JaNets installed on another PC,
you do not need the TraceMonitor option.
TraceMonitor
Equipment Manager
Data Manager
JaNets Instruction Manual
1. Overview
1-8
System Configuration
1.3.1 Supported machine models
Item
Specifications
Supported machine models
Maximum number of machines that
can be connected to one production
line
10
RS-1/RS-1R *5
RX-7/RX-7R *5
RX-6(RX-6B*1)/RX-6R *5
KE-3010A/3020VA/3020VRA
KE-3010/3020V/3020VR
KE-3020/3020R
KE-2070/2080/2080R
KE-2050R/2055R/2060R
KE-2050/2060
FX-3/RX-3R/FX-3RA
KD-2077
JX-350 *2
RV-1 *3
RV-2 *3
RV-2-3D *3
RP-1 *3
JM-10 *4
JM-20 *4
JM-100 *4 *5
Maximum number of machines that
can be created
50
200 when Data Manager is used
Maximum number of lines that can be
connected
15
*1 Treat RX-6B as RX-6.
*2 A JX-350 is supported in EPU mode only.
*3 The Equipment Manager license is required for a printer and an inspection machine
respectively.
*4 You cannot create any production line that connects a mounter, an adhesive dispenser and an
inserting machine.
You can create a production line configured of a printer, an inspection machine and an
inserting machine.
*5 Machine models supporting TraceMonitor.
Specifications of a used PC
1.4.1 JaNets PC
Specifications of a PC on which the JaNets operates are shown below (note that you have
to use a keyboard/mouse/printer supported with the Operating System (OS)).
Recommended specifications
CPU
Intel Core i3 3.0GHz or higher
Memory
8 GB or more
HDD capacity
500 GB or more
Available hard-disk space
50 GB or more
CD-ROM drive
1 or more
Screen resolution
FWXGA 1366×768 pixel or higher
Interface
1000BASE-T LAN connector (RJ-45) × 1
USB 2.0/3.0 × 1
OS
Microsoft Windows 10 Pro (64bit)
*1 A “DPI setting” for screen supports “normal size (96 DPI)” only.