JANETS_INM - 第23页

JaNets Instr ucti on Man ual 1. Overview 1- 10 Si mul tan eous S tar t - up of Applica tion Progr ams The corr elation of ap plicat ions that c an start up at the same time o n the P C is s hown belo w . User Manag ement…

100%1 / 755
JaNets Instruction Manual
1. Overview
1-9
1.4.2 Data Manager PC
The specifications of a PC on which Data Manager operates are shown below (note that you have
to use a keyboard/mouse/printer supported by the OS).
Specifications of a PC on which Data Manager operates
CPU
Intel Xeon CPU (3.00 GHz) or higher
Memory
8 GB or more
HDD capacity
1 TB or more
It is recommended to create the drives C and D and use the drive D as the data
storage area.
HDD unoccupied
space capacity
250 GB or more
RAID is required for mirroring.
DVD
1 or more
Screen resolution
XGA (1024 × 768) or higher
Interface
Keyboard (USB 2.0/3.0 or mini DIN 6-pin) × 1
Mouse (USB 2.0/3.0 or mini DIN 6-pin) × 1
1000BASE-T LAN connector (RJ-45) × 1
* When a UPS is used, an I/F port compatible with the UPS is required separately.
* When a printer is used, an I/F port compatible with the printer is required
separately.
Back-up device
LTO-5 1.5 TB (when not compressed)/3.0 TB (when compressed)
OS
Microsoft Windows Server 2012 R2 Standard Edition (64bit)
Microsoft Windows Server 2016 Standard Edition (64bit)
Uninterruptible
power supply
system (UPS)
Approximately 100 minutes at 100 VA/70 W
(APC Smart-UPS 1000 or equivalent)
* Intel and Xeon are trademarks of Intel Corporation in the U.S.A. and other countries.
* Microsoft and Windows Server are trademarks of US Microsoft Corporation in the U.S.A. and
other countries.
Data Manager
JaNets Instruction Manual
1. Overview
1-10
Simultaneous Start-up of Application Programs
The correlation of applications that can start up at the same time on the PC is shown below.
User Management
Shopfloor Setup
Component Database *1
Language Changer
Program Editor
Job optimizer
Tact simulation
Feeder Set Database
Mark Database
FlexlineCAD
Machine Program Relator
Program Downloader
Nozzle data viewer
Snapshot Tool
Log Management Tool
User Management
×
Shopfloor Setup
× × × × × ×
×
Component Database *1
×
Language Changer
×
Program Editor
× ×
Job optimizer
× ×
Tact simulation
×
Feeder Set Database
×
Mark Database
×
Flexline CAD
×
Machine Program Relater
× ×
Program Downloader
× ×
Nozzle data viewer
× ×
Snapshot Tool
×
Log Management Tool
×
(: Can start up, ×: Cannot start up)
Component Database
(Function cooperating with the main unit)
*1 Simultaneous start-up is enabled when a Data Manager option is added to the system. This
is an application program other than Component Database described as the function
associated with JaNets in this Manual.
* You cannot start up two or more same application programs at the same time.
* Since the “Shopfloor Setup” is a function for changing the production line information, you
cannot start up any application that browses the production line information at the same time.
* When you use a Data Manager option, you cannot simultaneously start up “Shopfloor Setup”
and “User Control” with two or more JaNets systems connected to Data Manager.
JaNets Instruction Manual
1. Overview
1-11
Flow of PWB Production with JaNets
1.6.1 Basic Editor
The operation flow up to PWB production using Basic Editor is shown below.
<Movement of the data from the JaNets by using a USB flash memory>
For the RX-6, copy the production program (division file) created by a "Data creation" command to a
USB flash memory, and save in a drive D drive on a main unit side. For the RX-7, read a production
program from a USB port. Refer to the section “File Management (Explorer)” of the Instruction
Manual of the main unit.
Note: Never save any program to the drive C of the main unit.
<The notes at the time of production execution when the data is transferred with a USB flash memory
(RX-6)>
Use a production program of the main unit to produce PWBs.
Be sure to remove the USB flash memory stick.
Create Data
Component Database
: Creation of a production
program (execution of
optimization)
Use a USB flash memory stick
to copy a production program.
Shared function
: Configuration of a machine
: Registration of
component information