JANETS_INM - 第232页

JaNets In structio n Manual 7. Program Editor 7- 25 7.4.3 Editing component data Displaying the component dat a l ist When you se lect the “ C ompone nt Data ” from the tree v iew , the following scr een app ears. Co m- …

100%1 / 755
JaNets Instruction Manual 7. Program Editor
7-24
Clinch/ Clinch Support
If [Clinch] of Mounting Data Screen is [Clinch No. 1 ~ 4], perform the setting pattern which was set
by the clinch of component data is performed against the component at mounting point.
In case of [Edit] or [Ref.], Clinch Support Setting Screen is displayed.
Figure 7.4-31Clinch Supportscreen
<Operations of buttons when you select Edit”>
OK: Goes back to the Placement Datascreen, and saves the input data. NOappears in the Clinchcell.
Select: Goes back to the Placement Datascreen, and the selected mark ID is displayed in the Clinchcell.
<Operations of buttons when you select Browse>: The <OK> button is disabled.
Delete: Delete the Support Data.
Deletion is unable when the data using Support ID is existed.
JaNets Instruction Manual 7. Program Editor
7-25
7.4.3 Editing component data
Displaying the component data list
When you select the Component Datafrom the tree view, the following screen appears. Com-
ponent data not linked with any placement data is also displayed.
Figure 7.4-32 Component data list
TheCentering (nozzle number)item to be displayed varies depending on the machine model as
shown below. Only the Centeringitem corresponding to the machine model that configures the
selected production line is displayed.
When the selected production line consist of an RX-6.
Figure 7.4-33 Displayed nozzle pattern
The state indicated with each color on the Component Datascreen is described below.
Figure 7.4-34 Component data list displayed colors
* When you perform a key operation: Ctrl + drag and Ctrl + drop or Ctrl +C key and Ctrl +V key for
a line of data on the Component data list screen, you can overwrite the component data with the
copied data.
Pink: Component data not linked with any placement data.
Orange: Data on a component to be skipped.
Yellow: Not completed component data.
JaNets Instruction Manual 7. Program Editor
7-26
Basic Settingsscreen
This screen allows you to create the basic data such as the component type, component pack-
aging style, outer dimensions and centering method. When you double-click a line on the
Placement Data listor Component data listdescribed above, this screen appears.
Figure 7.4-35 Basic Settingsscreen
[When a production line includes a JM series machine]
Insertion componentand INS electrolytic capacitorare added to the component types.
[When a production line includes a JM series machine, a JX-350 and an RS-1]
Package Size is enabled. When the package size is used, the package size is used for the di-
mensions and outside dimensions of deciding default value.
OK: Validates the changed data.
You can enter up to 127 half-width characters here.
When you select Chip,its
bit map is displayed also.