JANETS_INM - 第256页
JaNets In structio n Manual 7. Program Editor 7- 49 Placement conditions screen ( RX -6 S eries ) Figure 7.4 - 67 Placem ent conditions screen (RX - 6 S eries ) T able 7.4 - 32 Placeme nt condition (RX -6 S er ies ) scre…

JaNets Instruction Manual 7. Program Editor
7-48
Table 7.4-30 Placement condition (3010-20 Series) screen items
Item
Description
Stroke
Selects either “stroke” or “load” as a specifying method for the stroke of the nozzle end at
component pick.
Vacuum Control
Specifies whether to adjust the vacuum time when a component is picked up.
To adjust the vacuum time, enter the adjusting time in ms.
*When you use a KE-3020 or a KE-3020R, the default value for a square chip whose size is
that of a 1005 chip or larger is different from the default value for other components.
Set the correct default value by selecting the “Yes ” radio button for the menu item “Adjust” with
the machine again for data created with JaNets.
- Fluxer: Specifies whether to perform flux applying process using a fluxer. To use the fluxer, the
centering condition is set to “Priority of vision centering.”
Table 7.4-31 Placement condition (3010-20 Series Fluxer) screen items
Item
Description
Stroke Sets how much stroke of the component for the top surface of the fluxer.
Select either “Stroke” or “Load” as the control method.
Bottom Dead Point Hold Time
Sets the wait time after the descent of the Z-axis of the head at fluxer transfer.
Fluxer Z Up/Down Sets the up/down speed of the Z-axis of the head when fluxer is transferred.
When “Load” is selected, the menu item “Fluxer Z down” is set to “FC speed.”
Transfer Pos.
Selects the fluxer transfer position.
Judgment value of solder in-
spection difference
Used for inspection to be performed at vision recognition before/after transfer.
This is a threshold value of brightness difference between two recognition visions.
This is an effective data when the rotary fluxer is used.
Threshold value of solder in-
spection
Used for inspection at vision recognition only after transfer.
Specifies the brightness power value.
This is an effective data when the rotary fluxer is used.
The fluxer can be set only when vision centering is used.
Therefore, if the nozzle to be set by vision is not a load nozzle, “Load” cannot be selected as the
control method.

JaNets Instruction Manual 7. Program Editor
7-49
Placement conditions screen (RX-6 Series)
Figure 7.4-67 Placement conditions screen (RX-6 Series)
Table 7.4-32 Placement condition (RX-6 Series) screen items
Item
Description
Load
When the nozzle for low load is selected by centering, low-load control is exerted.
If the high-load nozzle is selected, high-load control is exerted.
When a load is selected, the control method is displayed.
Pressure time
Sets the load applying time in the unit of ms.
This is an effective data when high-load control is used.
Vacuum Control
Specifies whether to adjust the vacuum time when a component is picked up.
To adjust the vacuum time, enter the adjusting time in ms.

JaNets Instruction Manual 7. Program Editor
7-50
Placement conditions screen (RX-7 Series)
Figure 7.4-68 Placement conditions screen (RX-7 Series)
Set the component picking up conditions of a high-speed head and those of a general-purpose
head respectively.
Table 7.4-33 Placement condition (RX-7 Series) screen items
Item
Description
Nozzle staying time
Set the time period while the nozzle stops at the component placement position (moving
down position) in order to place the component on a board securely.
Input range: 0 to 9999+
Placement height
offset
Set offset in height direction at the component placement position.
Input range -999.99 to 999.99. (Default: 0.00)
Blow Starting Tim-
ing
Select whether to start blowing before the nozzle moves down or after it moves down.
“Before” is selected by default.
H-axis two-step
control
Specify whether to control the nozzle moving up/down speed to place a component on a
board in two steps.
To control the speed in two steps, enter the height and speed to be controlled in two
steps for moving up and moving down the nozzle respectively.
Moving-down speed
(%)
Enter the override of the speed for moving down the nozzle.
Enter the lower speed than the value set in the “H(Pick)” field of the menu item “Override”
on the vision centering screen (RX-7 series).
Moving-up speed
(%)
Enter the override of the speed for moving up the nozzle.
Enter the lower speed than the value set in the “H(Pick)” field of the menu item “Override”
on the vision centering screen (RX-7 series).
Moving-down
amount
Enter the height at which the speed is to be changed when the nozzle is moved down.
Moving-up amount
Enter the height at which the speed is to be changed when the nozzle is moved up.