JaNets Instr ucti on Man ual 13 . Program D ownloa der 13 -5 13.4 M ain Scre en Configur ation Figure 13.4 -1 Main scr een ( Condition of the Line monitor) Line Information : Displays in formatio n on PWB productio n of …

JaNets Instruction Manual 13. Program Downloader
13-4
13.3 Menu Configuration
Table 13.3-1 Menu bar items
Menu item
Description
File (F)
Open (O)
Reads the production program file used for production.
Open with a Serial code (S)
Reads a production program file used for production from the
associated serial code.
Clear the production schedule list (C)
Clears planned production registered in the active production line.
Change Planned No. of PWBs (E)
Changes the planned number of PWBs set for PWB production with
a production program at the present. You cannot select this
command when you specify a reservation file to produce PWBs.
Next production program reservation
(N)
The next program to be produced is reserved and registered by the
production program.
Register the next reservation file (R)
Reserves and registers a reservation file to be used for the next
production when production is set to be performed according to a
reservation file.
Exit Program Downloader (X)
Quits the Program Downloader.
Production
(P)
Switching operation mode (S)
Switches the operation mode of the Program Downloader.
This command is enabled only when the External Output function
license is valid.
Download (D)
Downloads a production program from the specified reservation file
or downloads the specified production program.
Termination Production (X)
Terminates or cancels the PWB production. If the system cannot
terminate the PWB production forcibly, this command is displayed in
gray and you cannot select it.
Individual Machine (I)
Specifies the desired machine on the selected production line to
download or upload data to/from the machine.
Download data for teaching (T)
Downloads a production program for teaching component pick-up
coordinates.
Upload data for teaching (U)
Uploads a production program for teaching component pick-up
coordinates.
View (V)
Line Monitor (M)
Line (L)
Displays each production line on the Line Monitor (default).
Floor (F)
Displays each floor on the Line Monitor.
All Lines (A)
Displays all production liens on the Line Monitor.
Floor Map (M)
Displays the floor map on the Line Monitor.
Number of components (O)
The information on the number of components is displayed and the
setting of the number of components is executed.
Feeder Layout (F)
Displays the feeder layout.
Nozzle Layout (N)
Displays the nozzle layout.
Supervising Condition (W)
Displays the monitored conditions.
Line Explorer (E)
/ Program Explorer (E)
When not Connecting to a Server
Displays/hides the Line Explorer.
When Connecting to a Server
Displays/hides the Program Explorer.
Toolbar (T)
Displays/hides the toolbar.
Status Bar (S)
Displays/hides the status bar.
Tool (T)
Deletion of pick coordinate
succeeded data (D)
The pick coordinate succeeded data is deleted.
Association of a serial code (A)
Associates a serial code with a production program.
Set Environments (E)
Makes settings of operations of the Program Downloader.
Setup Views (V)
Sets the items to be displayed on the data screen.
Help (H)
Table of Contents (C)
Displays the table of contents.
Toolbar
Table 13.3-2 Tool bar items
Tool button item
Description
Download
Downloads a production program from the specified reservation file.
Termination
Production
Terminates or cancels the PWB production. If the system cannot terminate the PWB
production forcibly, this tool button is displayed in gray and you cannot select it.
Line
Displays each production line on the Line Monitor (default).
Floor
Displays each floor on the Line Monitor.
All Lines
Displays all production liens on the Line Monitor.
Floor Map
Displays the floor map on the Line Monitor.

JaNets Instruction Manual 13. Program Downloader
13-5
13.4 Main Screen Configuration
Figure 13.4-1 Main screen (Condition of the Line monitor)
Line Information:
Displays information on PWB
production of a production line.
Production Status:
Displays the PWB production condition of
each machine of a reservation file and that
of a production line.
Displays the signal light, the
machine No., the machine ID and
the board transport direction.
Machine condition
Line Explorer: Displays
the production line
configuration and the
monitored condition.

JaNets Instruction Manual 13. Program Downloader
13-6
13.4.1 When Connecting to a Server
When you select the <Use> button for the menu item “Server” on the “Set Environments” screen of
the JaNets Launcher, the Program Explorer is displayed instead of the Line Explorer.
Figure 13.4-2 Main screen (when the Data Manager is used)
Data Manager
Program Explorer:
Displays a list of production
programs, the production line
configuration and the
monitored condition.