CP40 service manual - 第127页

4. Feeder Base & ANC (CP-40) 4-1. Trouble Diagnosis Guide Table Malfunction ANC Cylinder ANC Connector Pin Chec k 1 Feeder I/F Board Connector Check 5 ANC Coordinates Modification 4 Head Compliance O -Ring C heck 3 A…

100%1 / 250
3. X-Y PART
(CP-40)
Version Date WA QA CA Note
00 Nov04 O O O
4. Feeder Base & ANC
(CP-40)
4-1. Trouble Diagnosis Guide Table
Malfunction
ANC Cylinder
ANC Connector Pin Check 1
Feeder I/F Board Connector Check 5
ANC Coordinates Modification 4
Head Compliance O-Ring Check 3
ANC Shutter Parallelism Check 6
ANC Shutter Foreign Material
Removal
2
Multi Cylinder Connector Check 1
Multi Cylinder Replacement 5
Speed Con Adjustment 2
Feeder I/F Board Replacement 4
Multi Cylinder Air Check 3
Parts
Symptom
Check and Action
# Number Indicates Priority of Check Items
4. Feeder Base & ANC
(CP-40)
NO Symptom Possible Cause Error Code Action
Instructio
n
1
ANC Malfunction
ANC Connector Pin Check
Modify ANC Connector Pin.
4-3-2
2
Modify Feeder I/F CN No.3 and CN No.4
Connector Pins.
4-3-2
3 Bad AC Power of Front ANC Panel AC Modify Connector Pin. 4-3-2
4 ANC Shutter Check
Remove Foreign Materials from ANC Shutter.
5
Bad Recognition of Nozzle
Modify Coordinates of ANC. 4-3-4
6 Replace O-Ring.
7
ANC Shutter Malfunction
Reassemble ANC.
8 Clean with ANC Shutter WD40.
9
Cylinder
Malfunction
Multi Cylinders Operates with them
Exchanged.
Modify Wiring. 4-3-2
10
Multi Cylinder does not Operate.
Check Connector Pin for Bad Contact. 4-3-2
11 Replace Multi Cylinder. 4-3-5
12 Replace Feeder I/F Board. 4-3-1
13
Slow Cylinder Speed
Adjust Speed Con. 4-3-5
14 Check Multi Cylinder Air. 4-3-5
4-2. Trouble Diagnosis