CP40 service manual - 第216页
11. Utility (CP-40) 11-1. Trouble Diagnosis Guide Table # Number Indicates Priority of Check Items. Electricity Air Pressure Trans Former Power Supply Air Filter Tubing and Fitting CP Re placement 4 Power Supply Replacem…

10. Cover
(CP-40)
Classification
CP-40LV =>Addition(261) CP40-CV=>Cancellation(262)
Material No. Part Nomenclature Qty. Section Material No. Part Nomenclature Qty. Section
COVER
J7052010B COVER-R.F.U 1 J7052007B COVER-R.F.U 1
J7052011B COVER-L.F.U 1 J7052008B COVER-L.F.U 1
J2101832 COVER-R.R.U 1 J7052009B COVER-R.R.U 1
ACRYLIC C0VER
J2100030 WINDOW FRONT 1 J2101712 WINDOW FRONT 1 Front
J2101724 WINDOW REAR 1 Rear J2102264 ACRYLE COVER -REAR 1 Rear
J1300643 DOOR CATCH(MSW-01) 2 F:1, R:1 J2102266 TRAY COVER 1 Front
J7152018B CE VCOVER 1 Front
J7252011B MULTI STICK COVER 4 Front
BRACKET
J1301638 HANDLE 1 Front
J1301639 HINGE[E6-10-301-10] 2 Front
J2101708 HINGE NUT 2 Front
J2101710 SPACER,SWITCH 2 F:1, R:1
J2101711 BLOCK,SWITCH 1 Front
J2101714 STOPPER,COVER 2 Front
J2101715 STAYS,PLATE 1 Front
J2102267 BRACKET TRAY COVER 2 Front
J2102268 PLATE,ACRYL SUPPORT 2 Rear
J2102270 DOOR STOPPER 2 Front
J2102272 BRACKET HINGE NUT 4 Front
J1301640 DOOR SWITCH 2 F:1, R:1
J1301641 OPERATION KEY [D4DS-K3] 2
J1300638 HINGE[FTH7650H(IMAO)] 2 Rear
Cover and Bracket Types Change List of CP-40C(V) (Compared with CP-40L(V))
J1301638 : Modify Required Quality of BOM(2ea=>1ea) : Only 1ea is used(Modification of BOM is required).
J2100031 : It exist in CP-40C Part List.=> Modify BOM(?) : Iit used only for L(Modification of BOM is required).
J1300638 : Modify Required Quality of BOM(6ea=>2ea) * Verification is required. : 4ea for L and 6ea for C are required.
Version Date WA QA CA Note
00 Nov04 O O O CV

11. Utility
(CP-40)
11-1. Trouble Diagnosis Guide Table
# Number Indicates Priority of Check Items.
Electricity Air Pressure
Trans Former Power Supply Air Filter Tubing and Fitting
CP Replacement
4
Power Supply Replacement
5
OP Panel SW Replacement
OP Panel SW Soldering Check
Lamp Replacement
3
Power Supply Cable Check
2
AC/DC Line Check
3 2
Cable Disconnection Check
4
Power Supply 24V Output Check
1
Main Power Input/Output Check
1
Circuit Break Check
5
Water Removal from Air Filter
1
Drainer Tube Connector Check
2
Filter Element Replacement
3
Tube Disconnection Check
1
Fitting Looseness Check
2
Parts
Symptom
Check and Action

11. Utility
(CP-40)
NO Symptom Possible Cause Error Code Action
Instructio
n
1
Trans Former Malfunction
Low Input Voltage Modify Disconnected Cable. 11-3-2
2 Noise Tighten Bolts on Main Power Connector. 11-3-2
3
Power Supply
24V is not Output. Modify Disconnected 24VG and 24VP. 5-3-2
4 Bad Stick Feeder 24V Perform Lining AC/DC. 5-3-2
5 Front AC Power Malfunction Modify Disconnected Cable. 5-3-2
6 When Checking I/O, 24V Down Modify CV CN 37 Pin. 5-3-2
7
Air Filter Malfunction
Foreign Materials in Main Air
Clean and Replace Main Filter.
11-3-5
8
Foreign Materials in Air Filter RemoveWaterfromAirFilter.
11-3-5
9
Drainer Tube Connector Check Connect Connector.
11-3-5
10
Bad Filter Element Replace Filter Element.
11-3-3
11
Bad Tubing and Fitting
Tube Disconnection Check Tube Disconnection.
11-3-3
12
Fitting Looseness Tighten or Replace Fitting.
11-3-5
13
Air Pressure Error
Air Pressure Gage Check
Check Air Pressure Gage Level.
11-3-4
14
Check Air Pressure Gage Connector for
Disconnection.
11-3-4
15
16
17
18
11-2. Trouble Diagnosis