CP40 service manual - 第46页
MODULE ERROR CODE Symptom and Cause ACTION Service Manual Motor & I/O Part $F816 Vision interface error VISStart Error occurred when checking the internal SystemSystem. Try to recover the system with Stop/Reset or Em…

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$F80C
Task suspend error EATask
Error occurred when checking the internal System.
$F80D
Task Kill error Restart
Error occurred when checking the internal System.
$F80E
Task resume error Restart
Error occurred when checking the internal System.
$F80F
Event flag creation errorMotFlagInit
Occurs when connection with Axis Board is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F810
Event flag clear errorMotFlagClr
Occurs when connection with Axis Board is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
12-3-2
$F811
Event flag pend errorMotWaitS
Occurs when connection with Axis Board is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
12-3-7
$F812
Event flag pend errorMotWaitM
Occurs when connection with Axis Board is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F813
Vision interface error VISPause
Error occurred when checking the internal SystemSystem.
$F814
Vision interface error VISOut
Error occurred when checking the internal SystemSystem.
7-3-1
$F815
Vision interface error VISWait
Error occurred when checking the internal SystemSystem.
Try to recover the system with Stop/Reset or Emergency Stop/Reset.
If failed, try again after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
Check that VISION BAORD(ADDA, DSP) and CABLE is secured properly.
Try to recover the system with Stop/Reset or Emergency Stop/Reset.
If failed, try again after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
Replace O-ring and re-fasten Spindle securely.
- 33 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
Motor & I/O
Part
$F816
Vision interface error VISStart
Error occurred when checking the internal SystemSystem.
Try to recover the system with Stop/Reset or Emergency Stop/Reset.
If failed, try again after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
Check that VISION BAORD(ADDA, DSP) and CABLE is secured properly.
7-3-1
$F81E
Key(Jog) box TX error
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
$F81F
Key(Jog) box interrupt TX error
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
$F820
Key(Jog) box Semaphore error
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
3-3-3
$F821
Key(Jog) box Semaphore initialize error
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
5-3-2
$F822
Key(Jog) box Communication Error [0x22]
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
9-3-2
$F823
Key(Jog) box Communication Error [0x23]
Occurs when connection with teaching box is bad.
Occurs when condition of teaching box is bad.
$F830
Motor Interrupt error in x axis
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F831
Motor Interrupt error in y axis
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
Disconnect the teaching box from a system and connect again it.
Check a system with Emergency Stop/Reset.
If same teaching box exists, replace it.
Try to recover a system after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
- 34 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$F832
Motor Interrupt error in z axis / Head #1
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F833
Motor Interrupt error in z axis / Head #2
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
Check a system with Emergency Stop/Reset operations.
If failed, try to recover a system after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
$F834
Motor Interrupt error in z axis / Head #3
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F835
Motor Interrupt error in rotation Head #1
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F836
Motor Interrupt error in rotation Head #2
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
$F837
Motor Interrupt error in rotation Head #3
Occurs when connection with axis board related is bad.
Occurs when jumper for Interrupt link is not installed or connection is unstable.
Error occurred when checking the internal System.
Motor & I/O
Part
$F899
Task inquiry error Rtask
Error occurred when checking the internal SystemSystem.
Check a system with Emergency Stop/Reset operations.
If failed, try to recover a system after Power On/Off.
Error may be occurred frequently or recovery can not be executed however some measures are
given with above corrective actions.
PMT Error
Code Table
$100,
$101, 0,
$102, 0,
"[PCB] ", "Fiducial Mark Type=%d Fiducial Mark No.=%d "
PCB width is incorrect.
PCB width shall be 30~400mm(for 3-stage Conveyor) and 50~400mm(for 1-stage Conveyor).
Width of No.2 Board Size in "PCB Setup/Board-Definition" Dialog Box of MMI exceeds the range
above.
$103, 0,
"[PCB] ", "Fiducial Mark Type=%d Fiducial Mark No.=%d "
X value of part original point is incorrect.
X value of part original point shall be in system area.
Abnormal condition occurs to X value of Placement Origin in "PCB Setup/Board-Definition" Dialog
Box of MMI.
"[PCB] ", "Fiducial Mark Type=%d Fiducial Mark No.=%d "
PCB length is incorrect.
PCB length shall be 50~460mm.
- 35 -